Loading...
2002-03-05 Prelim Plat, Site Plan Review CUP/PUDNORTHWEST ASSOCIATED CONSULTANTS, INC. 5775 Wayzata Boulevard, Suite 555, St. Louis Park, MN 55416 Telephone: 952.595.9636 Facsimile: 952.595.9837 planners@nacplanning.com PLANNING REPORT TO: Albertville Planning Commission FROM: Cindy Sherman DATE: March 5, 2002 RE: Albertville — Albertville Crossing - Preliminary Plat, Site Plan Review, CUP/PUD FILE NO: 163.06 — 02.01 _ �tI3�1�ID Oppidan Investment Company has submitted an application for Preliminary Plat, Site Plan and Building Review, and PUD/CUP. The application is being made to allow the platting and development of a grocery store including a gas/convenience store, video store and liquor store incorporated into the design on one lot and a shopping center on a second lot. The balance of the plat includes one additional buildable lot and two outlots for future platting. The PUD/CUP is proposed to allow multiple uses and shared I arking. SUMMARY Preliminary Plat The preliminary plat consists of Lots 1, 2, and 3, Block 1 and Outlots A, B, and C plus right-of-way for the frontage road to be constructed to serve the site. Lot 1 is 6.12 acres and is the proposed site for Coburn's. Lot 2 is 4.14 acres in size and is the site for the strip center. Lot 3 is 1.28 acres in size and has no use proposed at this time. The lot will be subject to site plan review in the future. Outlot A is anticipated for future platting into multiple lots for development. Outlot B is 3.57 acres in size and will remain as open space for ponding purposes. Outlot C is 1.22 acres in size and will be platted in the future for development. The City Council recently reduced the park dedication requirements and how it is collected. Commercial dedication is $5000 per acre, net of outlots. In this case, 11.54 acres are being platted in three lots. This requires $57,700 in park fees to be paid prior to recording the final plat. Additional fees, at the rate in effect at the time of final plat, will be required if the outlots are platted for development. Zoning for the site is split. Lots 1, 2, 3, outlot B and the southerly portion of outlot A are all zoned B-2. The northerly one half of outlot A is zoned B-3. The underlying districts will generally be used for analysis of the site design although the PUD/CUP allows flexibility from the dimensional regulations. Site Plan Review Lot Area, Setback, Height and Coverage Requirements B-2 District Required Proposed - Coburn's Proposed - Center Lot Area 10,000 6.12 acres 4.14 acres Lot Width 100 feet 687+ feet 420+ feet Setbacks Front 35 feet 110 feet 235 feet Side 20 feet 40 feet 45 feet Rear 20 feet 115+ feet 29 feet Building Height 35 feet 28 feet 26 feet Maximum Maximum Lot coverage for 30 % of lot area 18.75% 14% Structures The proposed improvements are in compliance with all lot area, width, setback, height, and lot coverage requirements. Site Uses: The uses on the site are generally proposed to be retail sales and service. The Coburn's facility includes the main grocery store with accessory uses to include liquor sales, gas/convenience, video rental and pharmacy. The shopping center may include retail sales; service, such as hair or nail salons; take out food or restaurant, etc. All of the uses are permitted under the existing zoning except the gas sales. Lot 1, Block 1 requires rezoning to B-3 to allow the gas sales that are proposed. The applicant has shown gas sales on their concept plan and on this plan. It was a planning staff oversight that this was not picked up in our earlier review. If the City finds the use acceptable with this review, staff will process the rezoning immediately and the use can be approved contingent upon completion of the rezoning. Site Access: There are two accesses shown onto the property from 57th St. and two off of the frontage road proposed with the development. All accesses shall conform to any recommendations of the City Engineer. Parking: Parking for the grocery store is shown at 266 stalls plus 10 designated for disability accessible parking. The ordinance requires a total of 247 stalls. Up to 10 of the stalls may be utilized for cart corral storage. There are 207 stalls provided for the shopping center plus 4 disability accessible spaces, the ordinance requires 124. Some 4 of the parking constructed at this time for the shopping center may be used in the future for development of Outlot C. The parking spaces and drive aisle widths all meet or exceed the ordinance requirements. Curb and gutter will be installed around the perimeter of the parking lot and all islands within the lot and along the front and sides of the buildings. Building type and construction: The Coburn's building is proposed to be 50,000 square feet in size and will be one level. The exterior of the structure is proposed to be constructed of predominately Random Rib Precast Panel with rock face block and stucco enhancements at the entrances on the north and west sides of the building. Prefinished metal canopies are also proposed at the entrances and the drive-thru pickup window for the pharmacy. Staff has suggested use of a different type of precast panel that would be more architecturally pleasing and less industrial looking. A mix of materials to provide some visual break should be provided on the east and south sides of the building. The shopping center is proposed to be constructed of rock face block with accent banding provided around the sides and rear of the building. The front of the building incorporates a variety of designs and materials to create individual storefront appearances. Materials include stucco, scored concrete block, rock face block, glass and metal canopies. A mix of materials or design should be included on the rear of the building and sides of the buildings to break up the long wall Both of the structures have exposure to adjacent residential areas so treatment of the backs of the buildings is important. Signage: A comprehensive sign package has been submitted for the property and the applicant is looking for flexibility to allow the signage as proposed. Signage requested includes: Signs Area Identification Monuments Wall Number 1 — includes center name Currently 2* One per and 6 tenants tenant Location Corner of Co. Rd. 19 & 57 At westerly access on 57 On buildings St. and northerly access on frontage road Size 250 sq. ft. per face (2) 80 sq. feet per face 15% not to exceed 100 square feet Height 35 feet 12 feet I 36 inches *As outlots are platted, additional monument signs will be added. 3 Exterior Storage: The trash area is shown adjacent to the building for Coburn's with two locations next to the drive aisle on the rear of the shopping center. All will be enclosed and will be constructed of materials to match the building. Grading/Drainage/Utilities: The final plans are subject to the review and approval of the City Engineer. Landscaping Plan: A detailed landscaping plan has been submitted that provides a variety of trees and shrubs and does a good job of enhancing the screening of the large berm on the rear of the store. Financial security to guarantee the installation and survivability of the improvements shall be provided as required by ordinance. Lighting: A lighting plan has been submitted that shows using shoebox style fixtures with one to four heads per pole in the parking lot. The plan shows wall pack units on the rear and sides of the buildings. The lights proposed on the building need to be modified to have a shielded light source in order to prevent glare to adjacent residential uses. Street lighting will be required and the layout is subject to the review and approval of the City Engineer. Fire Dept. review: Comments will be provided as they are received. RECOMMENDATION Staff recommends approval of the Preliminary Plat, Site and Building Plans and PUD/CUP with the following conditions: 1. The City Attorney shall draft a PUD/CUP agreement for City Council approval outlining the conditions of approval and development allowed on the site. 2. Park dedication shall be a cash fee in lieu of land and shall be paid prior to recording the final plat for the buildable lots. Future platting of buildable lots will require additional dedication paid at the rate in effect at the time of the plat. 3. Approval is subject to Lot 1, Block 1 being rezoned to B-3 and the CUP/PUD shall include gas sales. 4. Access, grading, drainage and utility plans are subject to the review and approval of the City Engineer. 5. Signage shall be permitted as outlined in the Architectural Design standards and herein. 6. The site is subject to the review and comment of the Fire Department. 7. Exterior materials for Coburn's shall be modified prior to City Council review and some decorative elements shall be continued onto the rear of both structures. 8. Security to guarantee the installation and survivability of the landscape plan shall be provided prior to release of a building permit. 9. Lighting on the building shall be modified to include a shielded light source to prevent glare into the neighboring residential property. PC Linda Goeb, Pete Carlson, Dennis Crowe, Mike Couri 4 Adil =5EH MEMORANDUM 113 S. FIFTH AVENUE, P.O. BOX 1717, ST. CLOUD, MN 56302-1717 320 252-4740 800 572-0617 320 251-8760 FAX TO: Linda Goeb City Administrator Albertville, Minnesota FROM: Peter J. Carlson, P.E. City Engineer DATE: February 8, 1999 RE: Site Plan Review Albertville Crossings Albertville, Minnesota SEH No. A-ALBEV 9901.00 I reviewed the site plan for the above referenced development and have the following comments: Preliminary Plan 1. Maintain sanitary sewer easement along Lachman Avenue at its current width. Repairs to the sanitary sewer, if necessary, would be accomplished by slip -lining the pipe. Due to the depth of the sanitary sewer, this would have been the preferred repair method regardless of the proximity of the proposed buildings. Grading and Drainage Plan 1. The drainage calculations have been reviewed and found to comply with City standards. Since this development will be built in phases, the drainage calculation would be reviewed again when future phases of the development are implemented. 2. The proposed commercial property south of 57th Street drains to a proposed sedimentation pond in Outlot A. The pond's outlet into a wetland area within Outlot A which then drains to the large wetland area between Lachman Avenue and Lambert Avenue. The large wetland outlets into an existing storm sewer system in Landers Avenue. This proposed drainage system complies with City standards and with the City's storm sewer plan. An Affirmative Action, Equal Opportunity Employer 0 0 Linda Goeb Page 2 February 8, 1999 3. The proposed commercial property north of 57th Street drains to either 57th Street or to the north to an existing drainage swale along the north property line of the development. This drainage flows through the wetland complex and drainage system within the Sunrise Commercial Park, eventually draining across I-94 and into School Lake. This area will require storm water detention in accordance with City standards. A storm water detention pond has been located just south of the new ice arena. There may be opportunity to expand this pond to accommodate the storm water from the north portion of the proposed development. 4. Drain tile is required in accordance with City standards in the rear yard area of the single family lots are not adjacent to a wetland or storm water detention pond. The drain tile is intended to provide an outlet for sump pumps that would be installed in each home. 5. The wetland mitigation plan will be approved by the Wright Soil and Water Conservation District. The developer should be aware that the District has strict criteria regarding avoidance of wetlands wherever possible. Utility and Street Plan 1. Frontage Road would be considered a commercial/industrial road and shall comply with City standards. These standards include an 80-foot right-of-way and a 45-foot street width. 2. The southern portion of Lachman Avenue would be considered a residential street and should follow residential standards. Widen the portion of Lachman Avenue, north of the detention ponds, to commercial/industrial road standards. 3. The minimum size of water main shall be 8 inches. Revise plan accordingly. 4. It appears there is an excessive amount of sanitary sewer proposed in the commercial portion of the development. Revisions to the plan would not be necessary until future phases of the development are implemented. As you are aware, 57th Street is being constructed as a City project. The street will be constructed to commercial/industrial road standards. The street will be widened at the intersection with CSAH 19. Four lanes are proposed at the west end of 57th Street with a center concrete median. A 6-foot wide concrete sidewalk is proposed along the south side of 57th Street. A 12-inch water main is being planned to connect to the existing 16-inch water main along CSAH 19 to the existing water main at the east end of the proposed construction. This size water main is necessary to provide good fire flow to a commercial area. An Affirmative Action, Equal Opportunity Employer Linda Goeb Page 3 February 8, 1999 Please call me if you have any questions. dj g c: Albertville Planning Commission Mike Couri, City Attorney Alan Brixius, City Planner Todd McLouth, John Oliver and Associates. 1:\albev\coa\W8a-99.wpd An Affirmative Action, Equal Opportunity Employer