Loading...
2001-12-26 MN Pipe & Equip Submittal . . . MINNESOTA PIPE & EQUIPMENT 5145 211 th Street West · P.O. Box 249 FARMINGTON, MN 55024 651-463-4554 Fax 651-463-6090 Submittal Information Contractor: Kuechle Underground Job Name: Albert Villas Job City: Albertville Bid Date: private Engineer: Plowe Engineering Inc. Notes: i L \ \ } \I>cc/{ ~ ,~ \ 1.---'\ 800-325-5636 C" ' ~,)lf \ ~~~~ ---r rl LI:--'~)--./ Po E. LZc. ~ Lf IZ,S MINNESOTA PIPE & EQUIPMENT 612-463-6090 5145 211th Street West. P.O. Box 250 FARMINGTON, MN 55024 612-463-4554 Fax 800-325-5636 . Copper Tubing . . I'IH/";-J.:>-J.:>:>:> J....).J.O ~ ..~ ,_.... "! ..o.... ......';....'; \ ~~, I ~ .. .f, ~ ,'-" ",:~": ,,~.: ,.;t:HU ll'll:l I UDt: r-. IOJ./ lOb " . MATmtIAt' SAFETY' DA'TA . ~ET En'ECTIVE DATE; Nove1llber 25 ~ 1985 !WruTACTURER I S NAME: MANUFAC'I'UREk. t S ADDRESS: tMEkGlmCY TELEPHONE 1m.: - ReAding Tub~ Cot'por.ation' -P.O. ,Box 14oi6' , ' ' , Reading. PA 19612~4026 _,215'7926-4141' ' -..,-- V ) \lye r'e f ,~ ,v-~ SECTION I SUBST~CE'IDENTIF!CATtON T " ... PkODUCT NAME: Copper Tubing CHnttCAL NAME: Copp~ StNONn!S: Phosphorous Deondized Copper couform!Ui to AS'l'M C-122. l>UARTMENT OF tRANSPORTATION: Razard Classification, ShipP1ug N&1lle: None CAS #7440-50-8 CAS NAME: Copper Section' II PllYSICAL DATA -- . Bonma POUlT: 760 tnlll' Hg 4653.:5",(2S676C) Melting Point; 194601" (1083"C) SPECIFIC GRAVITY: 8.9 Vapor Pressure a~ 2962"F: 1 mm Hg SOI,tmItlTY IN 'W'A'l'Ek: . Insoluble SOLVENT SOLUBILITY; N:lt1:1c AC:lc:t; 'Sulfurtc Acid APPEARANCE AND CotOR.: l.edc!1.sb, tu.stro~, Ductile, ~lleabl. Metal SEcnOR, UI HAZAaDoUS INGREDltN'rS MATEkIAL % Tt'l HAZABD Copper 99.96 to See Sec:tiOllV ~s, DUSts, or Kista are 99.99 i~itan~~, skin sensitizer, and combustible or .explo.. s1~e with ignition source. "'--- .' '~ !1:SDS 111, PAGlI; 1 OF 6 ~ . . . . : MH~-l~-l~~ l~:l~ ~cH!J!NU IUtlc \ ..1 . ~ ..",- 0/ ~. .1 SECTION' IV FmE AND EXPLOSION DATA' fIU AND EXPLOSION 1tAZAIU) OF CO'PnR TDBnrG: None !"mE .AND IXPtOSION BAZABD. OF COPPER. DUSTS. MISTS, 1'UMEs, AND POWD~: Flmmnable or =:Plos1ve !hen"expos-ed' to heat ot' flame. CO"ppeTTubin~ Copper Dust: Mist. and Fum. FLASItPOmT: EXTINGUISHING MEOlA: None Flammable None lteq' d Use dry sand. dry dololll::Lte. dry graphite. or sodium chloride. Do not use wat:*~. SPECIAL 'FIn: TIGHTINc Noue Req'd For containers, remove from area (if possible), ~ool containers With water. For fi~as in enclosed araas, us. unmanned hose bolder or ll1otdt:or no~zles; else withdrawal, and let fire bum. SECTION V H!:.U.TH l1AZAml DATA 'tOXICOLOGY: IU;noDUCTIVE EFFECTS (a'I'EC):' None TUMOltIGl:NIc DATA (RTEC): None CARCINOC1!:N SUTUS: None ORt-HMN 'l'Dt.O r 120 MG/KG EXPOSURE .I..DttTS AND Ttv' 8 Copper Tube: None Copper Dusu, Mtst! a:nd Fumes: F\lII1es: 0.1 MG/~ TWA, OSHA 29 en 1910.1000, T~ble Z-l . 0.2 MG(CU)MG TWA. ACGIH, 1985-86 Dusts an~ Mists: 1 MG/l{3 'I'W'A, OSHA 29 em 1910.100, Table 1 MaIM mA, ACGIn (Notice of inte.nded de1et1ol\ n.v's 1985-1986) Coppe.r dusts, miacs,. and f\lmes are alc1n. eye and mucous lI1e1Db~ane irritants and skin sensiti2et'B. Persons With chronic re8pira- tOT'Y and skin disorders may be at: increased rtsk ,frOQl ~xpo.ure. MSDS '1, PA~ 2 OF 6 o 1".02/1216 .. ...... . . . MH~-l~-l~~~ l~:l~ , ' " , ' J,:~-' I ,.;~ ~:;i! ',~ ~~H!J1Ni..:l IUJ:i~ 1"'.10,;5/106 " . .' I, HEALTH mEet's OF COPPER DUST, MIST AND FUMES: SW'AttOWINC: Aeute exposur~ may caus-e gastrointestinal ini.tat1on characterized by inflammation, n.ausea, '\7omiting, and ten~S1lll1S, W'a.i.k:ne.s aucl cOllapse. ~hrot1~ eXposure 'lIIay eaUIJe kidney ~d liver damage. SKIN 4!SORPTION: Not-absorbed through t:ha skin. nmALATION; .' staN'CONTACT: nE CONTACT: SWALtOWING: SKIN: . INHALATION: EYEs: ~ eXPosm-e may caUse ma~al fUllle fever. Charactarizea by chills, fever, aching muscles, dryness in mouth ~d thraat"'W'1th met albic U.ste, headaches, sneezing, I1'8USes. and "'i:rrl:tat1on of noSa and C1'achea.' Occ.a.sdonal ulceration and perforation, of the nasal septUlll. Higher e-xposuree may lead to hemolysis, ja.undice, antit-ia, hypotension, and convul$ions. Chrmnc ~osu:e tIlay -result in conjuncti'\7iti~ and corneal des~ruction. Aeu~e ~d' chronic exposure mB,y cause sen8iti~ation derma~i~~s. ACute exposure may caUse irrieation. redn!!..s, JIluscuiar aches, nausea, and 'Vom:Lting. ~ e O$ure may cause irritation, redness, pain. and corneal turbi ity. Chronic -ekpDsure may result in conjunctivit:1s and ~Qal d~struction. SECTION VI _1l"IR.ST AID tf person is cbnc:io\ls. gi'\7e large amounts of ~ater i'lllll1ed:lately and induce vomiting. Do not lIlake an unc~eioU8....Rerl!lon. vomit or .drJ.nk. anythin~ Qualified. peX'Sonnel shOuld remove pouon by gastric lavage 01' eusis. Give aet:1vated charcoal. Maintain .airway and blood Pr'essure. Give o~gen if r.~p1rat1on ie depressed. Get medical attention. (Dreisbach, Handbook of Po1son~ng, 11th Ed.) lte1llove cont:am1nated Clothing. Wash sItt.n with soap and r1n8e wi th water. Remove to fresh air. I.f b-reathing' has stopped. giva &'t"tific18.J. resp1t'ation. Keep person 'W'a~. Get meaical attention. ImmediAtely flush eyes with water, oeeasionally lif~inc Upper and lower lids fOT 15 to 20 minutes. Get medical atten~ion. ....~ M;;DS #1, PAGE 3 OF 6 o . . . rHK-~~-~~~~ l~:l~ KI:.HU!Nl.:l IU.l:l1:. " . , .. ,'. . ~:"" , ' l~ \ .' - . . NOTES TO PlrrSICUN: ANTtnO'J:E: G1v8 15-25 MG/KG (0.08-0.125 ML of 20% sOlution per kilogram. of body lIeicht) Calcium Disodium Edetate in '250-500 ~ " of 5% deX1:rose 1nt1"&venously over a 1 to 2-hour period twice daily. The maximum dose should not exceed' .50 MG/KG/DAY. The drut should be giv~n in 5-day Cou~ses with rest period of at least 2 day, betwaen C~UrSe8. After the f~rst course. 5ub;equent couraes f;hould not exceed 50 Me/KG/DAY. Daily urinalyses" should be done during the treatment period. The dosage should be reduced if any unusual urinary find1ugs' appear. . Intravenous administration is contraindicated in the presence of elevated cerebrospinal fluid pressure. Administration of drug; and t~eatment should be performed h, qualified medical personnel. (Dreisbach, Handbook of Poi~oning) 11th Ed.) SEC'tION VI REACTIVITY DATA STABILr!Y: STA!L~: X UNSTABL~: .__ CONDITtows TO AVOID: Copper:ls readily attached by o~diz1ng aci4s or their aqueo~ solutions, dilute nitric acid. sulfuric aaid, hot Hydrobr~c acid. and other or~anic acids. INCOMPATIBILITIES: T'he brOtnate. e.hloroate, and iodate forms of barium. calcium, magnesium, potassium, sodi'Utll or duc eombined with copper C4Il produce an exp~Os1ve,r*action ~th heat, impact or friction. Copper in co=bination with e.hlorates or sulfur may create an explosive reaetton. In the presence of a=monia and water vapor, Copper and acetylene.can combine to form explosive Copper acetyltde. Copper in combination with chlorine and O~gen difluoride may create an explosive reaction. Co~per 1n combination w!th lead azide or sod1~ azide may create an e~loSive'co~ound. Copper in combination with l-Bromo-2~Propyn8 or Ql;hylene OXide lIlay ereate an explosion. Capper in combination wir:h chlorine 'trifluoride, potassuim diOXide, ammonium nitrate. aulfur:lc acid, hydrogen perOxide, Or hydrORRQ sulfide may creaee an intense chem1cal react1on. Copper in comD~nation with chlorine, fluorine. ' hydraz1nium nitrate, sodium perOXide" phosphorous. or po~assium dioxide ma.y create an ignition or inc~de8eent reac.tion. crystal~ne aIllJllonium perchlorate may be ignited when in contact with hot c.opper pipes. Copper is slowly aetached by cold, hydrochloric acid and d~lute sulfuric acid. COpper is readily attached by nitric aC1d. sulfuric acid, acetic acid, and other organia acids. HSDS 111, PAGE 4 . OF 6 i~ P.04/06 'V'r . . . IYIH/'(-l ':;1-1 '::1':;1':;1 1,,); 1 ':;I I'<t:.Hl.JLNI..'l IUl::St:. " \ . ." . (') ~t. " DECOMPOSItION: Thermal decoMpoSition th1;'ough 1Ilelt1ng of the copper metal or through ehemical reaction may release toXic or hatardous gases. BAZAkDous POLYMERIZATION: WIllI. NOT OCCUR: X MAY OCCUll: SECTION VII SPILt OR tEAK PROCEDURES STEPS to BE TAlCEN D' MAn::aw. IS REI.EASttl OR SPILLED: No spil1 procedures are necessary for eopper tubing. Y01:' SPilled cop'Per dust, m1s t s or powder: Shut off' :i.~ition Sourc~s. Do not touch spilled. material. For small spills shovel material into clean. d1')' container and cover; move containers frODl. spill area. For larger spills. wetdo'lm with wa~er and dike for la~er d13posal. ~o smoktng, flames or flares in hazard area. Keep unnecessary people away. Isolate hazard area and deny entry. Residue. should be eleaned up -USing a high-etficiency particulate filter vacuum. :For spills ~ water. use activated carbon to ab.sorb diSsolved metal; U$e suction hoses and dredges to remove settled particulate mater1al. WAS'!E DISPOSAl., METHOD: (FOR SPILLED DUST, ~ST, OR POWD~.) . , Dispose of ~ontaineri%.d material in a liscensed landfill according to appropriate federal. state and loea! regulations. . SECTION VIII SPECIAL ~RO~CTION INFORMATION RESPUATCRY PROTECTIO~; For prOtQction a~a1nst copper fume; 1 MG(CU)/M3 - Use h!gh efftQ!ency part1cula~e re$pirator as mini~ prot~et1on. s MG(Cu)/~ _ Use high ~ff1c1ency partiCUlate respirator with a full-face- piece. Mst>s 111. PAGE S"07 6 t} t".IO~/lOb "J '''r . . . MAR-19-1999 13:19 READING TUBE P.06/06 "... . .... .." ~ !.;:".I:' ~SPIRATOR.Y nOttCTION (Continued from page ,5): For CO~per fume protection (Continued): 100 MG(Cu)/M3 - Us. powQ~ed ai~-purifYing respirator With high efficiQncy filter. .! .. '. '. ~.. ~ 200 MG (eu) /~. - Use type ItC" suppl1ed air-respirator with a full f4ce.piece operated in pressure demand or positive pressure mode. For dust Or Uist protact1on: 50 MG~ Use high efficiency part1culate respirator ~ith a full face piece. 2000 !1c/u3 Use type tIC"~ supplied air respi2:"ator with a full !ace piece operated in pressure de~and or Positive p~es$ure mode. VENTILATION: . Provide loeal exhaust to meet TLV's (See Section V) where USe of copper tube produces COpper dustt llliet or fume. EYE PROTECTION: trse splash proof or dWl~ resistant safety goggles ~here e~osure is to coPper dusts, mists, and funte.s~ PROTECTIVE' CLO'l'HING: Wear apprOPriate protective clothi.ng to preVent prOlonged exposure or COPpet' dust. mi~t; OJ:' fUll1e to akin. OntER PROTECTIVE EQUIPMENT; Eye bath and showers. SECTION IX SPECIAL PRECAUTIONS ~- P~CAOTIONS TO :BE TAREN IN HANDLING ANn S'rORING: Where Wle of the copper tub!ng produce. a copper powder, dust, lUst or fume. (1) ~plOYees should not eat or smoke in these areas; (2) employees should change into clean clothing when leav-ing work; (3) lUIIployees should ~ash hands thoroughly before eating, smoking, or usinC toilet facilities. *************************************************************~********* .* NOTE~ The opinions e~ressed he~Qin are based on the current info~-* · tI1at1on as'of the date of this Material Safety Da~a Shee~, Because ~ * the Use of this information and the conditions of use of the product~ * are not ~thin the Control of Readina rndustr~es, the .user is re- ~ * sPonslble to dete~ne the conditions fo? safe use of this prcduc~. * ********************************************k****~********************* o MSDS Ill. PACF. Ii . n'll' ~ TOTAL P. 136 Ford Stainless Steel Saddles .tyle FS303 for Standard and/or C900 PVC Pipe . Stainless Steel Bolts and Nuts 18-8 type 304 Stainless Steel Bolts. Heavy hex nuts are fluorocarbon coated to prevent ,allio,. ~ Stainless Band Heavy gauge 18-8 type 304 Stainless Steel. 4" wide on 2" and 3" sizes. 6" wide on 4" through 12" sizes. All welds are fully passivated to restore stainless steel characteristics. Stainless Taps 18-8 type 304 Stainless Steel TIG welded to shell. Available with AWWA, FIP., or BSP threads 3/4" thru 2". Washers Special Nylatron GS* washers are also provided for added lubrication. Gasket Buna-N ASTM D2000 rubber. Coined Body with recessed O-Ring or Flush Body with tapered gasket. Pressure Rating The Ford FS303 is rated for 150 psi. Bolt Chart Two 1/2" Bolts Two 5/8" Bolts Four 5/8" Bolts . *Nylatron GS is a registered trademark of the Polymer Corporation. To Order: Add Tap Code Number to Catalog Number. For example: a saddle for 8" PVC with a 1" CC tap would be FS303-905-CC4. 2.38 FS303-238- Ta 2.88 FS303-288-Ta 3" 3.50 FS303-350- Ta 4" 4.50-4.80 FS303-48o- Ta 4.2 5" 5.56 FS303-556- Ta 4.8 6" 6.63-6.90 FS303-690-Ta 5.1 8" 8.63-9.05 FS303-905- Ta 5.6 10" 10.75-11.10 FS303-1110-Ta 8.6 12" 12.75-13.20 FS303-1320- Ta 9.1 OUTLET THREAD TAP CODE . .~~:(~WWA)r@EAD . rIiR~j:) . CODE No. 3/4" CC CC3 1" CC CC4 1-1/4" CC CC5 1-1/2" CC CC6 2" CC CC7 FIPTHRE:Al:1 THREAD CODE No. 3/4" IP IP3 1" IP IP4 1-1/4"IP IP5 1-1/2" IP IP6 2" IP IP7 B$'~'l)iRI;All....... THREAD CooliNo. 3/4" BSP BSP3 1" BSP BSP4 1-1/4" BSP BSP5 1-1/2" BSP BSP6 2"BSP BSP7 . AA-24 . Ballcorp TM Corporation Stops - (FB600-x style) SUBMITTAL INFORMATION AWWAlCC TAPER THREAD INLET BY FLARE COPPER OUTLET Solid one piece tee-head and stem. t Inlet L Molded Buna-N rubber seats support the ball. EPDM O-rings in the stem. Body Outlet Threads Outlet . I Length Spherical fluorocarbon-coated brass ball. VALVE SIZE INLET SIZE OUTLET SIZE VALVE BODY OUTLET ApPROX. PART " SUBMITTED LENGTH THREADS WT. LBS NUMBER ITEM(S) 3/4" 3/4" 3/4" 4-7/16" 3/4" Flare Coooer 1.8 FB600-3 3/4" 3/4" 1" 4-9/16" 1- Flare CooDer 2.0 FB600-34 1" 1- 1" 4-9/16- 1" Flare Copoer 2.8 FB600-4 1-1/4" 1-1/4- 1-1/4" 6-1/4" 1-1/4" Flare CoOi er 5.0 FB600-5 1-1/4" 1-1/4" 1-1/2" 6-9/16- 1-1/2- Flare Co 01 er 5.6 FB600-56 1-1/2- 1-1/2" 1-1/2- 7-1/8" 1-1/2" Flare Co 01 er 7.1 FB600-6 1-1/2" 1-1/2" 2" 7-9/16" 2" Flare Coooer 9.4 FB600-67 2" 2" 2- 7-9/16" 2" Flare Coooer 12.0 FB600-7 FEATURES · All brass conforms to AWWA Standard C800-89 (ASTM 8-62 - 805.05, UNS NO C833600 - 85-5-5-5) · Ends are integral or secured with adhesive to prevent unintentional disassembly. · 300 PSI working pressure. The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. . ~ The Ford Meter Box Company, Inc_ I J I P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 219-563-3171 1 Fax: 800-826-3487 Overseas Fax: 219-563-0167 http://www.fordmeterbox.com ISUbm"ed By: 08/21/97 Ford Minneapolis Pattern Curb Boxes Minneapolis Pattern Curb Boxes with 1" Upper Section Stationary Rod Included ./A. {.~- '-'- . Type HS Lid - 2 hole style "Erie Pattern" <It ___ c' n \-</:.)./ ../ f,\. ,/I 7) r::J~(:J / . Type PS Lid - Plug style with standard pentagon bolt (e EM1-30-46-18R 3' 18" 16.0 EM 1-35-46-24R 3-1/2' 24" 17.0 EM 1-40-46-30R 4' 30" 19.0 EM1-45-46-36R 4-1/2' 36" 20.0 EM 1-50-46-42R 5' 42" 21.0 EM 1-55-46-48R 5-1/2' 48" 22.0 EM 1-60-46-54R 6' 54" 24.0 EM 1-65-46-60R 6-1/2' 60" 25.0 EM 1-70-46-66R 7' 66" 26.0 EM1-75-46-72R 7-1/2' 72" 27.0 EM 1-80-46-78R 78" 28.0 EM1-30-47-18R EM1-35-47-24R EM1-40-47-30R EM1-45-47-36R EM1-50-47-42R EM1-55-47-48R EM1-60-47-54R EM1-65-47-60R EM1-70-47-66R EM1-75-47-72R EM1-80-47-78R 16.0 24" 17.0 4' 30" 19.0 4-1 /2' 36" 20.0 5' 42" 21.0 5-1/2' 48" 22.0 6' 54" 24.0 6-1/2' 60" 25.0 7' 66" 26.0 7-1/2' 72" 27.0 8' 78" 28.0 EM2-30-46-18R EM2-35-46-24R EM2-40-46-30R EM2-45-46-36R EM2-50-46-42R EM2-55-46-48R EM2-60-46-54R EM2-65-46-60R EM2-70-46-66R EM2-75-46-72R EM2-80-46-78R 18" 16.0 24" 17.0 4' 30" 19.0 4-1/2' 36" 20.0 5' 42" 21.0 5-1/2' 48" 22.0 6' 54" 24.0 6-1/2' 60" 25.0 7' 66" 26.0 7-1/2' 72" 27.0 8' 78" 28.0 ApPROX. WT. LBS. 16.0 17.0 19.0 20.0 21.0 22.0 24.0 25.0 26.0 27.0 28.0 . TYPE.PS LII;), JPL ., . 6ASE TA~P .. !;XTENDED LBNGTtl 3' n CATALOG NUMBER EM2-30-47-18R EM2-35-47-24R EM2-40-47-30R EM2-45-47-36R EM2-50-47 -42R EM2-55-47-48R EM2-60-47-54R EM2-65-47-60R EM2-70-47-66R EM2-75-47-72R EM2-80-47-78R 3-1/2' 4' 30" 36" 42" 48" 54" 60" 66" 72" 78" 4-1/2' 5' 5-1/2' 6' 6-1/2' 7' 7-1/2' 8' GA-5 ; . SUBMITTAL INFORMATION . Ball Valve Curb Stop - (B22-xxxM style) MINNEAPOLIS PATTERN - FLARE COPPER BOTH ENDS IfF A restraining ring locks the stem into the body of the valve. Solid one piece tee-head and stem. Sturdy stops allow 900 motion and are enclosed and protected. Threaded body for Minneapolis Style . ./ Curb Box ./ Molded Buna-N rubber seats support the ball. ~ .. , , .. , , .. ,," ,.. + t- Outlet f_ . Length Spherical fluorocarbon-coated brass ball. VALVE SIZE INLET SIZE OUTLET SIZE LENGTH ApPROX. PART ....; SUBMITTED WT. LBS NUMBER ITEM(S} 3/4" 3/4" 3/4" 4-1/4" 2.9 B22-333M 3/4" 1 " 1 " 4-1/2" 4.1 B22-344M 1 " l' 1 " 5-1/16" 4.2 B22-444M 1 " 1-1/4 ' 1-1/4" 6-1/2" 5.6 B22-455M - 1-1/4 " 1-1/4 ' 1-1/4 " - 4.2 B22-555M 1-1/2" 1-1/2' 1-1/2" 8-1/4" 11.0 B22-666M 2" 2" 2' 8-5/8" 17.4 B22-777M FEATURES · All brass conforms to AWWAStandard C800-89 (ASTM 8-62 - 805.05, UNS NO C833600 - 85-5-5-5) · Valve is non-directional and is water tight with flow in both directions. · Ends are integral or secured with adhesive to prevent unintentional disassembly. · Hole for attaching curb box rod or handle is provided in Tee-Head. · 300 PSI working pressure. . The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. ~ The Ford Meter Box Company, Inc. I I I P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 219-563-3171 1 Fax: 800-826-3487 Overseas Fax: 219-563-0167 http://www.fordmeterbox.com I Submitted By: 09/02'''')"7 For use in municipal water systems, .J.lrelines and other .itical services. Strength Class 100, 150 and 200 Blue Brute water pipes have long-term hydrostatic strength that meet the commonly accepted high safety requirements of municipal water systems. Blue Brute conforms to cast iron O.O.'s and is available in 4", 6", 8", 10" and12" sizes in Class 1 00, 150, and 200. Meets AWWA C900 Underwriters Laboratories and NSF 61 Listed, Factory Mutual Approved. J-M Manufacturing's Blue Brute Class 150 and 200 PVC water pipes are listed for critical use in firelines and water mains and are F/M approved. Blue Brute Class 100 is intended for water mains. ~ht weight foot length of Class 150, 8" Blue ..te water pipe weighs approximately 181 pounds. That makes it easy to load, easy to transport and easy to handle. Installers prefer it because it goes into the ground quickly - thus saving on installation costs. Long laying lengths A standard laying length of Blue Brute PVC water pipe is 20 feet. That means you can cover a lot of ground during installation. At the same time, you eliminate the cost of unnecessary joints. . Corrosion resistance Blue Brute is unaffected by electrolytic or galvanic corrosion, or any known soil or water condition. You don't have to worry about tuberculation, or the need for costly lining, wrapping, coating or cathodic protection. Quality control Without exception, each length of pipe is hydrostatically tested and subject to inspection by our quality control inspectors throughout every step of the manufacturing process. Flow capacity This PVC water pipe has a smooth interior that stays smooth over long years of service with no loss in carrying capacity. Its coefficient of flow is C = 150 (H&W) - the best available in common use in water systems. This capacity often allows savings in pumping costs as well as savings on the size of pipe required. Field cutting You can cut Blue Brute with a powersaw or an ordinary handsaw. It eliminates the need to invest in costly cutting equipment. r \~ Service life Because it is nonmetallic, the pipe does not lose strength due to either potable water corrosion or external galvanic or soil corrosion. And its design includes a surge allowance for a 2 ft./sec. stoppage of flow. Ring-Tite joints with factory installed rings Blue Brute's Ring-Tite joint can be assembled quickly. Seated in a deep groove, the flexible elastomeric ring provides a tight seal that protects the line from shock, vibration, earth move- ment and compensates for expansion and contraction of pipe lengths. And there's no field miXing or application of cement. It's a simple push-together joint that remains tight under normal operating conditions. Ring-Tite joint with factory installed ring factory installed rubber sealing ring provides tight, flexible seal Spigot pipe ends are supplied from factory with bevels. f). '"-- The bell is an integral part of the pipe length with the same strength. Installation Product should be installed in accordance with J-M Publication TR-704B, "Blue Brute@ PVC Class Water Pipe, Installation Guide." 0,' \.< /' '" . 2 Flow characteristics and dimensions . Flow chart Class 100 (DR 25) Velocity Head loss Velocity Head loss Velocity Head loss Velocity Head loss Velocity Head loss ft.!sec. psi/100' ft./sec. psi/100' ft/sec. psi/100' ft.!sec. psi/100' ft/sec. psi/100' Gals.! Pipe size (in.) min. 4 4.391.0. 6 6.30 J.D. 8 8.28 J.D. 10 10.16 J.D. 12 12.08 I.D. 100 2.12 0.16 200 4.24 0.57 2.05 0.10 300 6.35 1.21 3.07 0.21 400 8.47 2.07 4.10 0.35 2.38 0.09 500 5.12 0.53 2.98 0.14 600 6.15 0.75 3.57 0.20 2.38 0.07 700 7.17 0.99 4.17 0.27 2.77 0.10 800 8.20 1.27 4.76 0.34 3.17 0.13 2.24 0.05 900 9.22 1.58 5.36 0.42 3.56 0.16 2.52 0.07 1,000 5.96 0.51 3.96 0.19 2.80 0.08 1,500 8.93 1.09 5.94 0.40 4.20 0.17 2,000 7.92 0.69 5.60 0.29 2,500 9.90 1.04 7.00 0.45 3,000 8.40 0.62 . 3,500 9.80 0.83 Class 150 (DR 18) Gals.! Pipe size (in.) min. 4 4.231.0. 6 6.09 J.D. 8 7.981.0. 10 9.79 J.D. 12 11.651.0. 100 2.28 0.19 200 4.57 0.69 2.20 0.12 300 6.85 1.46 3.30 0.25 400 9.13 2.48 4.41 0.42 2.57 0.11 500 5.51 0.64 3.21 0.17 2.13 0.06 600 6.61 0.89 3.85 0.24 2.56 0.09 700 7.71 1.18 4.49 0.32 2.98 0.12 2.11 0.U5 800 8.81 1.52 5.13 0.41 3.41 0.15 2.41 0.06 900 9.91 1.89 5.77 0.51 3.84 0.19 2.71 0.08 1,000 6.41 0.61 4.26 0.23 3.01 0.10 1,500 9.62 1.30 6.39 0.48 4.51 0.21 2,000 8.52 0.82 6.02 0.35 2,500 7.52 0.53 3,000 9.03 0.74 Class 200 (DR 14) Gals.! Pipe Size (in.) Min. 4 4.07 1.0. 6 5.861.0. 8 7.68 J.D. 10 9.42 J.D. 12 11.20 J.D. 100 2.47 0.23 200 4.93 0.83 2.38 0.14 300 7.40 1.76 3.57 0.30 2.08 0.08 400 9.86 2.99 4.76 0.51 2.77 0.14 500 5.95 0.77 3.46 0.21 2.30 0.08 600 7.14 1.07 4.16 0.29 2.76 0.11 700 8.33 1.43 4.85 0.38 3.22 0.14 2.28 0.06 800 9.52 1.83 5.54 0.49 3.68 0.18 2.60 0.08 1,000 6.93 0.74 4.60 0.28 3.26 0.12 . 1,200 5.53 0.39 3.91 0.17 1 ,400 6.45 0.52 4.56 0.22 1,600 7.37 0.67 5.21 0.29 2,000 9.21 1.01 6.51 0.43 2,500 8.14 0.66 3,000 9.77 0.92 Coefficient of flow is C = 150 (Hazen and Williams). 3 Velocity and head loss data are based on nominal inside diameter, which is outside diameter minus twice thickness T (nom.), . Dimensions (average) Class 100 (DR 25)* loss Pipe Outside Nom. inside T (min.) E Approx. Wt. 10' size (in.) dia. (in.) dia. (in.)** thick. (in.) dim. (in.) 09 Ibs./ft. Lb. 4 4.80 4.39 .192 4.75 6.4 1.9 6 6.90 6.30 .276 5.50 8.8 3.9 8 9.05 8.28 .362 6.25 11.4 6.7 10 11.10 10.16 .444 7.00 13.8 10.1 12 13.20 12.08 .528 7.80 15.9 14.4 Class 150 (DR 18)* 4 4.80 4.23 .267 4.75 6.5 2.6 6 6.90 6.09 .383 5.50 9.0 5.3 8 9.05 7.98 .503 6.25 11.6 9.2 10 11.10 9.79 .617 7.00 14.1 13.9 12 13.20 11.65 .733 7.80 16.7 19.7 Class 200 (DR 14)* 4 4.80 4.07 .343 4.75 6.8 3.2 6 6.90 5.86 .493 5.50 9.4 6.7 8 9.05 7.68 .646 6.25 12.1 11.6 -- 10 11.10 9.42 .793 7.00 14.3 17.6 12 13.20 11.20 .943 7.80 16.9 25.1 ""DR (Dimension Ratio) is the outside diameter divided by the minimum wall thickness T (min.). **Nominal inside diameter equals the outside diameter minus twice thickness T (nom.). 1.0. 1 09 1.0. . 3 . ..~ . Accessories Blue Brute is backed up by all the items it takes for smooth installation of water pipe. Direct taps can be made with proper tapping tools. (See detailed instructions on tapping in the "Blue Brute Installation Guide", TR-704R) Cast iron 0.0. Available in 4", 6", 8", 10" and 12" sizes, this pipe can be connected directly into cast and ductile iron fittings without adaptors or complicated procedures. Short form specification Scope This specification designates general requirements for unplasticized polyvinyl chloride (PVC) plastic class water pipe with integral bell and spigot joints for the conveyance of water and other fluids. Materials Pipe shall meet the requirements of AWWA C900, "Polyvinyl Chloride (PVC) Water Distribution". All Class 1 00 pipe shall meet the requirements of DR 25, Class 150 pipe shall meet the requirements of DR 18 and Class 200 the requirements of DR 14. Pipe All pipe shall be suitable for use as pressure conduit. Provisions must be made for expansion and contraction at each joint with an elastomeric ring. The bell shall consist of an integral wall section with a factory installed, solid cross section elastomeric ring which meets the requirements of ASTM F-477. The bell section shall be designed to be at least as hydrostatically strong as the pipe wall and meet the requirements of AWWA C900. Sizes and dimensions shall be as shown in this specification. Joint design meets qualification requirements of ASTM F3139. Hydro Testing Each pipe shall be tested to four times the pressure class of the pipe for a minimum of 5 seconds. The integral bell shall be tested with the pipe. Standard Laying Lengths Standard laying lengths shall be 20 feet (:t 1 ") for all sizes. Pipe stiffness The pipe stiffness using F/!::,y for PVC class water pipe is contained in the table below: Class 100 150 200 DR 25 18 14 F /b.y (pSi) 129 364 815 Quick burst test Randomly selected samples tested in accordance with ASTM D 1599 shall withstand, without failure, pressures listed below when applied in 60-70 seconds. Class 100 150 200 Minimum burst pressure at 730F (pSi) 535 755 985 Drop impact test Pipe shall withstand, without failure at 730F, an impact of a falling missile, Tup C, at the following levels. (Per ASTM D 2444). Pipe size (in.) 4 6 8 10 12 Impact (ft./lbs.) 100 100 100 120 120 There shall be no visible evidence of Shattering or splitting when the energy is imposed. 5 e The physical (or chemical) properties of J-M products described herein represent typical average values ob- tained in accordance with accepted test methods and are subject to normal manu- facturing variations. They are supplied as a technical service and are subject to change without notice. e ./"1 ". ~ "--.j WARRANTY J-M warrants that its standard products are manufactured in accordance with its applicable material specifications and are free from defects in workmanship and materials, using J-M's specifications as a standard. Every claim under this warranty shall be deemed waived unless in writing and received by J-M within thirty (30) days of the date the defect was discovered, and within one (1) year of the date of the shipment. Claims for product appearance defects, such as sunbleached pipe etc., however, must be made within thirty (30) days of the date of the shipment. J-M must first be given an opportunity to inspect the product alleged to be defective in order to determine if it meets J-M specifications and if the handling, installation, and operating conditions have been satisfactory and in accor- dance with J-M recommended practices. Products sold by J-M which are manufactured by others are warranted only to the extent and limits of the warranty of the manufac- turer. The limited and exclusive remedy for breach of the above warranty by J-M shall be the resupply of a like quan- tity of non-defective product. J-M shall not be liable for any INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES OF ANY KIND, INCLUDING, WITHOUT LIMITATION, ANY EXPENSES FOR REMOVAL OR REINSTALLATION RESULTING FROM ANY DEFECT. J-M MAKES NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, IN FACT OR IN LAW, INCLUDING, WITHOUT LIMITATION, THE WARRANTY OF MERCHAN- TABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, OTHER THAN THE LIMITED WARRANTY SET FORTH HEREIN. Visit our website at www.jrnpipe.com J-M SALES & MARKETING / J-M PIPE CUSTOMER SERVICE CENTER 973/535-1633 OR 800/621-4404 eJ-M PIPE J-M Manufacturing Company, Inc. 9 Peach Tree Hill Road Livingston, NJ 07039 TRX-27 Rev. 6/99 8-Q, Inc. Made in USA . . . Uni-Flange Retainer (UFR1500-C-x style) 4" .12" UNI.FLANGE SERIES 1500-C "CIRCLE-LOCK" FOR C900 PVC PIPE Ductile iron actuating screw, with the Auto-TorkQl) break-away head design, ""~. prop,,""'"' \" ""'..,,,. _ Safety stop insures ring segments can never be over-tightened. ___Auto-TorkQl) Bolt ~R",~I", Segment -~ Gland body is of High Strength Ductile Iron per ASTM A536, Grade------ 65-45-12. Compatible with all mechanical joints conforming to ANSI/AWWAC111/A21.11. Bolt Hole Cross Section Ring Segments are ductile iron per ASTM A536 and heat treated to a hardness of 370 BHN minimum. Front Back NOM. CATALOG NUMBER No. OF ApPRox. PRESSURE PRESSURE RATING --JSUBMITTED PIPE O.D. AWWA C.900 RESTRAINT WEIGHT P1* PZ"* BC D RATING C-900 AWWA C-900 SIZE PVC PIPE SEGMENTS (LBS.) DR-18 DR.14 ITERM(S) 4 4.80 UFR 1500-C-4 4 10 12.1 10.0 7.5 4.9 150 PSI 200 PSI 6 6.90 UFR1500-C-6 6 14 14.1 12.1 9.5 7.0 150 PSI 200 PSI 8 9.05 UFR1500-C-8 6 18 16.2 14.3 11.75 9.15 150 PSI 200 PSI 10 11.10 UFR1500-C-10 8 25 18.3 16.3 14.0 11.20 150 PSI 200 PSI 12 13.20 UFR1500-C-12 8 29 20.3 18.4 16.25 13.30 150 PSI 200 PSI *Maximum 0.0. of gland on pipe before Auto-TorkQl) heads are removed (as shipped). **Maximum 0.0. of gland on pipe after Auto-TorkQl) heads are removed. FEATURES · Full circle contact and support of the pipe wall. The Series 1500 can be used on any thickness class of AWWA C-900 PVC pipe without any point loading. · "Auto-Tor~" actuating screws with heads specially designed to twist off at the correct installation torque, leaving a hex head in case future system maintenance or removal is required. · Restraining segments are mechanically retained in pockets, they cannot fall out. · When you use the Series 1500, there is no need to pour expensive and time consuming concrete thrust blocks. The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. IJD The Ford Meter Box Company, Inc. rbm,.ed By, I' I P.o. Box 443, Wabash, Ind,ana U.SA. 46992-0443 Phone: 219-563-3171 / Fax: 800-826-3487 Overseas Fax: 219-563-0167 http://www.fordmeterbox.com 08/23/00 ~ .lll..L;)\.IV - U'-'LJ..1.J.l'.l.J'-' ..1.Ju.a.l vV' all ~ ~.P"" .1 a.~1;; .1 VI L. . . . August 07,2001 GOLDFLO GOLDFLO WTIM sleeve coupler accessories spedfi ,at ions installation guide test results GOLDUNE GOLDUNE GLP ac.cessories Installation guide delivery farm drainage contractor's tooJbox about prinsco industry news tradeshow$ contact us site map home page DUAL. WAll PIPE Uses: High volume drain needs such as gravity storm sewers, culverts, highway drains, golf courses, agricultural mains and other fluid transfer applications Description: Plain End Pipe, Smooth Interior, Corrugated Exterior, Requires Split Couplers, Long Term Durability, Superior Flow Rates 'The Gold Stripe is your guarantee of quality!" - Larry Groen Prinsco General Manager Bottom Line Benefits: Easy to Handle + Lightweight = Faster Installations and Smaller Crews Unaffected By FreezelThaw Cycle + Does Not Rust or Corrode = Uncompromising Durability and Strength Prinsco's GOLDFL()@ Dual-Wall pipe with a plain end enjoys the same great characteristics as GOI.DFI.O WTTM . Its corrugated exterior combined with the smooth interior wall gives GOI.DFI.()@ the strength and flow characteristics to complete any high volume drainage application. GOLDFL()@ can be coupled by several means. Typical installations of GOLDFI.()@ will use a soil-tight split coupler to connect each length of pipe. Another option is a silt-tight coupler that employs a foam gasket to prohibit silt infiltration into the pipe. A watertight sleeve coupler provides a third choice when coupling GOI.DFL()@ plain end. Each ofthese coupling options will give you a fast and simple installation, yet retaining the strength and flow rates you expect from GOI.DFI.()@. As with GOI.DFI.O WTTM , GOI.DFI.O@ Dual-Wall Polyethylene Pipe is your best choice for long-term durability. It is chemical and abrasion resistant. It will not rust, corrode or deteriorate under freeze-thaw cycles. GOLDFLOO also exceeds AASHTO M 252, AASHTO M 294, ASTM F 405, AND ASTM F 667 requirements for dual-wall polyethylene pipe, with a Manning's "n" value of 0.012. (~r ,- '\ -{~J~' . :>"" v(~s (7,"~ \ ,,/ 2,.. ....,........\ \ '\:;lj;(lt f. \1 ....""".. ' LA')€. (D f'\ '1 lv'\ \ I /' Ii ," '\ 6-~->..?\, i''\lr""""1J\S " http://www.prinsco.com!goldflo . din 8/7/01 .........u.~""'V '-' '--' A...t/.JLJ1.... ~'-' ......, """""'-L ,.,.~........t'- . I Diameter II Number II Length II Unit II Wt.lLbs I *4" II 04DW20NP II 20' II Per Foot II .5 I 6" II 06GF20NP II 20' II Per Foot II 1.0 I 8" II 08GF20NP II 20' II Per Foot II 1.7 I *10" II 10DW20NP II 20' II Per Foot II 2.3 I 12" II 12GF20NP II 20' II Per Foot II 3.1 I 15" II 15GF20NP II 20' II Per Foot II 4.4 I 18" II 18GF20NP II 20' II Per Foot II 7.0 I 24" II 24GF20NP II 20' II Per Foot II 11.0 I *3D" II 3ODW20NP II 20' II Per Foot II 14.6 I 36" II 36GF20NP II 20' II Per Foot II 19.0 I 42" II 42DW20NP II 20' II Per Foot II 27.0 * Sourced from another manufacturer. . .~~. ! GOlDFlO I GOlOllNE I GOlOllNE GlP accessories I installation guide I deliverv I farm drainage about prinsco I prinsco news I trade shows I contact us I site map Home Page . http://www.prinsco.com!goldflo.cfin .&. .....0- ~ V,L ~ 817/01 I~~j 1.0 . 2.0 SDR 35 (PS46) FITTING SPECIFICATIONS GPK pvc Sewer Fittings shall be manufactured in accordance with either ASTM D 3034, F 1336 or F 679. The PVC material shall have a minimum cell classification of 12454-B, 12454-C or 12364-C as defined in ASTM D 1784. The purpose of GPK in-line fittings is to convey municipal sanitary 'and industrial wastes, storm water run-off and many other related applications. They are designed to be used in gravity flow and low pressure applications not to exceed 10.8 psI. 3.0 Injection Molded Fittings are produced in sizes 4' through 8' diameter. Fabricated Fittings are produced in sizes 4' through 27' diameter. A fabricated fitting is considered any fitting made from pipe or a combination of pipe and molded components. 4.0 Chemical Resistance. GPK fittings resist attack from certain alcohols, alkalies, salt solutions, acids and other types of chemicals. Refer to chemical resistance chart. 5.0 Marking. GPK fittings shall be marked with applicable size, 'PVC', company name or logo, PSM and the ASTM specification number (D 3034, F 1336 or F 679). The fittings and/or packaging shall include the manufacturer's date and shift code. 6.0 Testing. A test after installation of either low pressure air (Uni-B-6) or a water infiltration-exfiltration test is recommended. 7.0 Deflection Test. The maximum allowable pipe fitting deflection should be 7 1/2% of base ID as shown in Table XLI of D 3034. 8.0 Backfilling and Tamping. Backfilling should follow closely after assembly of pipe and fittings. . 8.1 Backfilling with proper material is important to achieve desired density in haunching area which enables pipe, fitting and soil to work together to meet designed load requirements. This eliminates excess deflectiqn and shear breaks due to heavy loads. Approved material shall be used properly, compacted continuously above and around the pipe and fittings as well as between the fitting and trench' wall. A cushion of approved material up to a minimum of 12' over the fittings and between the trench walls shall be applied in accordance, with the engineers' specifications. 8.2 Tamping. This shall be done by hand tamping of the embedment material betwef~n the trench wall of the service line fitting and riser connection. Tamping can also be done by mechanical tampers or by using water to consolidate the embedment material. Extreme unstable ground conditions may require wider trenches to enable you to compact a larger area around the pipe and fittings to the density consistent of the original ground surface conditions. 9.0 Service Lines. Normally, service lines from the property line to the collection sewer should be a minimum depth of 3 feet at the property line and should be laid in straight alignment and uniform slopEl of not less than 1/4' per foot for 4' nominal pipe and 1/8' per foot for 6' pipe. Where collection sewers are deeper than 7 feet a vertical standpipe of stack is permitted. Deep sewer chimney and risers necessitate extreme. care during backfilling. Where surface loading is anticipated the final backfill must be compacted to a density compatible with those surface loads to be encountered. 9.1 . SUMMARY: 296 Backfilling around pipe service laterals on slope. Extra attention should be given on slopes to prevent the newly backfilled trench from becoming a 'French Drain.' Before backfilling compietely there is a tendency for ground and surface water to follow the direction of the looser soil. This flow may wash out soil from under or around pipe and branch line fittings, reducing or eliminating the support needed. To avoid this problem the backfilling should be of greater compaction. Tamping should be done in 4' layers and continued in this manner all the way up to ground or surface line of the trench. Concrete collars or other concrete poured around the fitting to stabilize unwanted movement is recommended to prevent water from undercutting the underside of the pipe and fittings. Due to various ground conditions and different situations, installation techniques vary widely. We warranty our products to be free of manufacturer's defects. We wiil not replace the products that are Installed or used Incorrectly. The design of the systems that our product is used in Is a factor that cannot be overlooked. . . . GPK FITTING SUBMITTAL SHEET Intro: GPK manufactures PVC sewer fittings in accordance with either ASTM D 3034, F 1336 or F 679 to be used in gravity flow or low pressure applications. Injection molded fittings are produced in sizes 4' through 8' diameter. Fabricated fittings are produced In sizes 4' through 27' diameter. ~.'.';" ~)~i Material: Fabricated fittings are manufactured from PVC pipe and molded components meeting all the requirements of either ASTM D 3034, F 1336 and F 679 for workmanship, extrusion quality, stiffness, Impact resistance, dimensions and structural performance. Extruded pipe components are made from PVC material with a minimum cell classification of 12454-B, 12454-C or 12364-C as defined in ASTM D 1784. Injection molded fittings are made from PVC material with a minimum cell classification of 12454-B, 12454-C or 13343-C as defined in ASTM D 1784. Extrusion Quality: Extruded components are tested In accordance with and meet all requirements of ASTM D 2152 for properiy fused PVc. Impact Resistance: Extruded components are tested in accordance with ASTM D 2444 using a 20 lb. Tup A and a Flat Plate Holder B. The strength shall equal or exceed the values shown below: 4' - 5' 150 Ft-Lbs 6' - 8' 210 Ft-Lbs 10' - 27' 220 Ft-lbs Impact Resistance: Injection molded fittings are tested In accordance with ASTM D 2444 using a 20 lb. Tup A and a Fiat Plate Holder B. The strength shall equal or exceed the values shown below: 4' 50 Ft-Lbs 6' - 8' 75 Ft-Lbs Pipe Stiffness: Extruded components are tested in accordance with ASTM D 2421. The stiffness equals or exceeds the requirements of ASTM D 3034 and F 679 of 46 psi. . () Pipe Flattening: Extruded components are flattened as described in ASTM D 3034 and F 679 until the distance between the plates is 40% of the outside diameter of the pipe. There shall be no splitting, cracking or breaking. Pressure/Pressure Deflection: Gasketed joints are tested in accordance with ASTM D 3212. Pressure: 10 minutes @ 10.8 psi + 10 minutes deflected @ 10.8 psi. . Vacuum: 10 minutes @ 22' Hg + 10 minutes deflected @ 22' Hg. Branch Bending:The chemically fused areas around the branches of tee, '#'Ie and tee-wye fittings are tested toASTM F 1336 to verify their strength and integrity. Riser load: Tee and tee-wye fittings shall withstand a riser load of at least (100. TY .OD) pounds. No cracking or splitting shall occur. Joining Methods: Chemically Fused Solvent Weld Joints Solvent cement is handled and tested in accordance with ASTM D 2564 and D 2855. The lap Shear Strength shall equal or exceed 900 psi @ 72 hours. Heat Fusion Welded Joints (Butt Fusion Welds) Elastomeric Seals (Gaskets) Must meet all requirements of ASTM F 477 and D 3212. Saddles: Injection molded saddle tees and saddle wyes shall have skirts with a minimum of 80 square inches surface area which can be bonded to pipe. Fabricated saddle tees and saddle wyes shall have skirts with a minImum of 160 square inches surface area Which can be bonded to pipe. ~_. GPK does not recommend gasket skirts where air tests are required. 2 296 -. . . SPECIFICATIONS northern pipe products inc. 1302 39th st. nw. fargo, nd 58102-2808' phone 701-282-7655. wats 800-747-7655. fax 701-282-2887 PVC SEWER PIPE ASTM 0-3034 PSM Belled End Product Data Northern Pipe Products PVC Belled End Sewer Pipe is made from components conforming to material specification ASTM 0-1784, and meets all dimensional and physical specifications of ASTM 0-3034. 4-inch through 6-inch is manufactured in 10 foot overall lengths, while 8-inch through 1S-inch is 13 foot laying length. Size son 0.0. Wall Wt./Ft. Length Ft./Pallet Ft./T.L. 4" 35 4.215 .120 1.01 10' 600' 19,200' 6' 35 6.275 .180 2.26 10' 330' 7,920' 8' 35 8.400 .240 4.17 13' 312' 5,616' 10" 35 10.500 .300 6.55 13' 195' 3,510' 12' 35 12.500 .360 9.41 13' 104' 2,496' 15' 35 15.300 .437 14.16 13' 78' 1,404' PVC DRAINAGE PIPE ASTM 0-2729 Belled End Product Data Size 4' 6' 0.0. 4.215 . 6.275 Wall .075 .100 Wt./Ft. .64 1.27 Length 10' 10' Ft./Pallet 600' 330' Ft./T .l. 19,200' 7,920' NOTE: ASTM 2729 is available perforated: please note when ordering. SEWER AND DRAINAGE PIPE Solvent Weld Joint Dimensions Nominal Pipe Size Inches 4 6 8 10 12 15 Overall Spigot Insertion Depth "E" Inches 3.000 5.250 6.000 6.250 7.250 8.750 D E Socket Depth "0" Inches 2.750 5.000 5.750 6.000 7.000 8.500 CAT (K's) 7-94 1000 '. . . SPECIFICATIONS northern pipe products inc. 1302 39th st. nw. fargo, nd 58102.2808. phone 701.282.7655. wats 800.747.7655. fax 701.282.2887 PVC GRAVITY SEWER PIPE ASTM 0-3034 PSM Gasketed Pipe Product Data Northern Pipe Products PVC Gasketed Sewer Pipe is made from compounds conforming to the requirements of ASTM 0-3034 in accordance with ASTM 0-1784. Sewer Pipe 4 inch through 15 inch meets all dimensional and physical specifications of ASTM 0-3034. 18-inch Sewer Pipe meets all dimensional and physical specifications of ASTM F-679. 4-inch through 15-inch SOR-35 and 18-inch PS-46 are available with the CSA (Canadian Standards Association) mark of acceptance. All Gasketed Sewer Pipe is manufactured to laying lengths. SOR.41 SOR.35 SOR.26 Nominal Weight Weight Weight Pipe Pipe Min. Lbs./Ft. Min. Lbs./Ft. Min. Lbs./Ft. Size 0.0. Wall 13' / 20' Wall 13' / 20' Wall 13' / 20' Inches Inches Inches Lgth. Lgth. Inches Lgth. Lgth. Inches Lgth. Lgth. 4' 4.215 - - / - .120 1.04 / 1.03 .162 1.38 / - 6' 6.275 - - / - .180 2.32 / 2.30 .241 3.08 / - 8' 8.400 .205 3.59 / 3.54 .240 4.18 / 4.13 .323 5.57 / - 10' 10.500 .256 5.61 / 5.54 .300 6.55 / 6.46 .404 8.74 / - 12' 12.500 .305 7.96 / 7.85 .360 9.36 / 9.22 .481 12.41 / - 15' 15.300 .375 12.03 / 11.85 .437 13.97 / 13.75 .588 18.65 / - ASTM F-679 PS-46 T-1 Nominal Pipe Size Inches 18" *21" *24" *27" Pipe 0.0. Inches 18.701 22.047 24.803 27.953 Min. Wall Inches .536 .632 .711 .801 Weight Lbs.lFt. 21.03 29.50 37.58 48.75 Laying Len th 13' 12' 12' 12' *This information provided for reference. Northern Pipe Products does not manufac- ture sewer pipe over 18" in diameter. CAT (K's) 7-94 1000 SPECIFICATIONS "Quality" . NAME IN PVC PIPE northern pipe products inc. /) 1302 39th st. nw. fargo, nd 58102-2808. phone 701-282-7655. wats 800-747-7655. fax 701-282-2887 0-3034 GASKET JOINT PVC SEWER PIPE Northern Pipe Products PVC Gasketed Sewer Pipe is made from gasketed joints conforming to ASTM D-3212 (Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals). All gaskets conform to ASTM F-477 (Standard Specification for Elastomeric Seals for Joining Plastic Pipe). Spigot ends are beveled and insertion depths are marked for correct installation. LOCKED~IN GASKET JO!~!T E Pipe Dimensions in Inches Size Inches A B C D E 4 5.000 1.000 .750 4.000 3.750 6 7.150 1.250 .875 4.250 4.000 .8 9.500 1.500 .875 5.625 5.250 10 11 .700 1,500 1.000 6.250 5.500 12 13.800 1.500 1.125 6.500 6.250 15 16.900 1.750 1.400 7.000 6.500 18 20.650 2.000 1.500 7.500 7.500 ..: Locked-In Gasket Gasketed Joint Sizes 4" through 18" ) A. Gasket Groove (Race) O.D. B. Lip Length C. Gasket Groove (Race) Length D. Overall Joint Depth E. Spigot Insertion Depth . CAT (K's) 9-96 1000 . BpM Birmingham Fastener Manufacturing P.O. Box 10323 Birminghatn, AL 35202 (205) 595"3512 E-Mail: byin~@1>-hamfut.com July 3, 2001 To: Wade Minnesota Pipe (651) 463-4554 From: Blane Vines Re: Fluorocarbon VS. Core Blue . The fluorocarbon coating that is used on our T -head bolt is a coating that is equal to or superior to the Core Blue. Core Blue is not a coating type. It is a trade name used by my competitor to specify their fluorocarbon-coated bolt from their plain bolt. The only difference between the coating on our bolts and theirs is the manufacturer of the coating. Any specifications written that calls out Core Blue is referring to either my competitors coated bolt or my coated bolt. Please direct any questions or concerns about this matter from anyone writing or meeting specifications for jobs or municipalities to me for clarification. Sincerely, tLtL Blane Vines Quality Assurance . . . . --... Certificate of ConljJliallce Birmingham Fastener Manufacturing P. O. Box 10323 Birmingham, AL 35202 (205) 595-3511 Description of Material Item Description: 3/4-10 Fluorocarbon Coated T -Head Bolt Bolt Specification: ANSIJAWWA Cl11/A21.11-95 Coating Type: FluoroKote# 1 Raw Material Analysis 2 Material: Low carbon weathering steel Grade: ASTM A242 C 0.20 max Mn 1.25 max S 0.030 max Ni 0.25 min Cu 0 20 min Combined (Ni, Cu, Cr) 1.25 min Note 2: The raw materials analysis is taken from the chemical and physical requirements of AWWA Clll/A21.l1-95. Product Allalysis Yield Strength 45,000 psi min. Elongation in 2 inches 20 % min. Proof Load 13,OOOlbfmin. Coating Allalysis Thickness 0.0005 - 0.0025 in. Coefficent of Friction 0.02 - 0.10 ContillOus Use Temp. -420oF - 5000F Tensile Strength 2000-4000 psi Corrosion Resistance (Salt Spray ASTM B 117) up to 4000 hrs. This information represents the range of chemical and physical characteristics of the referenced item. Items sold by Birmingham Fastener Manufacturing under the above item description will meet the requirements above. Authorized Signature: jL~ Blane Vines Quality Assurance 2/11/00 Date: . . . fo: Blane Bines Dale: 2/10/00 Time: 5:40:40 PM Page 2, of 2 r Co~ e(V-e. Fluoro Kote#l@ Product Description: FluoroKote#1@ is a proprietary fluoropolymer coating process that has been used v<tensively in the petrochemical and oil industries since 1974. Due to its exceptional corrosion resistance. and low coefficient of friction, this process can increase the. life. and efficiency of various machined parts and tools and is on excellent coating for threaded parts of 011 types. This process offers exceptional ch~mical resistance (see page 2) and durability. The FluoroKote#1@ coating process produces 0 smooth surfoce. that provides the combined benefits of ontigauling and even, predictable torquing with easy installation and removal. Product Uses: FluoroKotc#l@ is in use on the following products: Valves, fittings, fasteners, metol gaskets, couplings. flanges, threaded connections, bearings, gears, pistons, hydraulic connectors, actuators, blowout preventer~, subsea wellheads, and many other products that may benefit from Q highly lubricious corrosion resistant dry film coating. Technical Data: Use Temperatures: Maximum Continuous. . . . . . . . . . . . . 5000F Maximum Short TC!rm. .... ....... 6000F Minimum Continuous. . . . . . . . . . . . . -420oF Dielectric Strength . . . . . . . . , .; . 1200-2000 volts per mil Codiclent of Friction . . . . . . . . . . 0.02-0.10 Adhesion to ~II Types of- Materials. . . . . . . . . . . . . . . Excellent Wear Resistance.. . . . . . ... . .. . . Excellent Operating Pressure. . . . . Up to 100:000 psi Thickness. . , . . . . _ _ . . . Minimum - 0.0005 in. . . . . . . , . . . . . Maximum... 0.0025 in. Ccrrosioal Resistance: Salt Spray (ASTM 9117) . . .up to 4000 hrs Tensile Strength. . . . . . . . . 2000-4000 psi Elongation . . " . . . . . . _ _ . . . . _ . . _ . 35'0-50'0 Water Absorption. .. . . . ...... ....0.0370 Metal Coatings Corp. - P.O. Box 630407 - Houston. Texas n263-0407 (713) 9n-0123 - Fox (713) 9n-0824 . . . { To: Blane Bines ,. Dale: 2/10/00 Time: 5:00:42 PM FluoroKote#l @ Chemical Resistance Data (Retained Strength after e><pc>sure to materillls for 24 hours at 200.F) Chemical Acids ....cetic (10%) Glacial Acetic Acetic Anhydride lactic BehZllfle Sulfonic Chromic (10%) Formic (88%) Hydrochloric (1O~) Hydrochloric (37%) Phosphoric (35%) Sulfuric (30~) Bases: Ammoniul'l\ Hydroxide (28%) Sodium Hydroxide (151.) ~odlum HydroxIde (30%) ",kohols 2-~minoethanol Al'I\yl Ethanol Butyl Ethanol Cyclohe)(onol Ethyltane Glycol Aldehyde~ & Ketones Acetonphenone 9cn%llldehyde CyelohelCOnone formaldehyde (37%) furfural AAethylEthyl Ketone Amlnes Aniline n-Butylamine Dlmethylanlline Ethylehediaminc Morpholine PyrldlO'lIl Aquzous Solutions (10% unless otherwise noted) Aluminum Sulfdte Ammonium Chloride Ammonium Nitrate Ammonium Sulfate (lor/urn Chloride Bromine tsaturatcd sol,120.F) Calcium Chloride Calcium Nitrate Ferric Chloride Magnesium Chloride Postssium PlZrmanganate Sodium BiearbohOte Silver Chloride Sodium Carbonate Pucent Retained strength Chemical Aqueous Solutions (cant'd) Sodium Chloride Sodium Chr-omate . Sodium Hypochlorite Sodium Sulfate: Sodium Sulfide Sodium Sulfite Wct~r Chlorinated Organics "'cetyl Chloride (120.f) Benzyl Chloride (120.F) Carbon Tetrachloride:. Chlorobenzene 2-Chloraethanol Chloroform (120.f) Epichlorohydrin Ethylene Chloride 100 100 100 100 28 100 66 100 95 100 100 81 43 7 9 100 100 100 100 Est~rs Amyl Acetdte Butyl Acetate Butyl Phthalate: Ethyl Acetate Ethers Butyl Ether Cellosolve p-Dixocne (120.1") . Tetrahydrofuran 100 100 100 100 84 100 HydraC4rbons Cydahexah Diesel fuel G<uoline (120.F) Heptane Mlrw:ral Oil Motor Oil Stoddard Solvent Toluene Xylene 97 100 100 7 100 43 100 100 98 100 100 100 100 96 99 100 100 100 100 100 Nitrilu ~u:tonitrile 8enzonltrile Nitro Compounds Nitrobenzene Nitromethane Miscellaneous Cresyldiphenyl Phosphclte Sulfolane Triphenylphosphite: Page.~ of 8 Percent Retained Strength. ,\ 100 100 100 100 84 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 99 100 100 100 loq 100 100 100 100 100 100 100 100 100 100 Mdal Coatings Corp. P.O. Box 630407 - (713) 9n -0123 Houston, Texas n263-0407 Fax (713) 9n-0824 .ii!!l!il"J7'Z11 .up'" 6860 SERIES CAST IRON THREE-PIECE VALVE BOXES for 3" through 20" valves, 5-1/4" shaft, screw-type (Base Required, Order Separatly) .Jew ways to save on valve boxes. Eliminate extra handling by buying pre- assembled units. Save on single parts and accessories. Lower unit cost by purchasing Valu-Paks of 30 to 80 pieces of tops and bottoms in crates. Three levels of pricing to keep you competitive. THREE WAYS TO SAVE 6860 BOX PRICES AT DIFFERENT LEVELS Levell Level 2 Level 3 Boxes Individual Parts VALU-PAK Parts Assembled Not Assembled Not Assembled Box Less Base/Less Lid Less Base/Less Lid Less Base/Less Lid AA 40.00 38.00 A 57.00 54.15 B 70.00 62.00 58.90 C 77.00 65.00 61.75 CC 83.00 73.00 69.35 D 100.00 83.00 78.85 DD 107.00 91.00 86.45 E 99.00 94.05 F 11 7.00 111. 1 4 G 128.00 121.60 Note: A "BOX" is one top and one bottom LEVEL ONE Boxes assembled/less bases & lids . r , I I I I I , I , , I / Base Illustrated '\ I For Position Only... '\ " Not Furnished '. I \ I , I I ."===== == = === = ===_ ..1.. "f)'" ~:....J Level Two Bottom LEVEL ONE: BOXES ASSEMBLED/LESS BASES & LIDS Box (Components) Extension UPC No. Weight List Price AA(lOT+ 12B) 27-37 (Not Offered Assembled) A( lOT + 18B) 33-42 (Not Offered Assembled) B(16T-24B) 39-49 145936 69 70.00 C(16T+30B) 45-54 145943. 73 77.00 (C(16T+36B) 51-61 145950 75 83.00 D(26T+30B) 45-66 145967 88 100.00 DD(26T+36B) 51-72 145974 90 107.00 E(26T+24B+#60 Ext) 63-72 (Not Offered Assembled) F(26T+24B+#60 Ext) 63-84 (Not Offered Assembled) G(26 T +36B+#60 Ext) 74-94 (Not Offered Assembled) Note: Order Required Lids & Bases Separately. 6 Box Assembled Tyler Pipe/Utilities Division · P. O. Box 2027 · Tyler, TX 75710 · (903) 882-5511 1-18-99 ~Tnll ~P/PI ,/ e.. LEVEL :t\NO~Parts:Not ;}~,",",>,,,.<,;/ . Box (Components) . M{10T+J2Bl A{16T+ 18B) B{16T+24B) C(16T+30S) CC{16T-36B) D{26T-30B) . DD(26T+36B) E{16T+24B+#60 Ext) F{26T+24B+#60 Ext) G{26 T +36B+#60 Ext) ~3-42 . 39-49 45-54 51 ~60 45-66 5J -72 63.72 63"84 74.94 ,-"-,' .z LIDS ("WATER") ItemiDlt~cription UP<: NQ. .5-1,14 Drop Lid 145325 $- t 14lQck Lid 14546'2 1-1/8 Riser Lid* 145509 *Used with 1-1/ 8"RiserOnly EXTENSIONS {e '\..,.. " Item/Description #58 Screw-Type #59 Screw- Type #60 Screw-Type UPC No. 145141 145158 145059 lte~/Description 5-1/4xl-1/8* 5-1/4~2-1/4 #69 Adjl1stoble *Vsed.withH/8"Lid UPC No. 145554 145547 1.48197 1 , 144946 144946 144946 144946 144953 144953 144946 144953 144953 Weight 13 18 11 List Price 12.00 21.00 12.00 6860 SERIES CAST IRON THREE-PIECE VALVE BOXES for 3" through 20" valves, 5-1/411 shaft, screw-type (Base Required, Order Separatley) 37.00 37.00 ,37.00 BASES List Price Item/Description #4, 11-1/4" Wide #6, 14~3/4" Wide #160,20,1/8" Wide UPC No. 145653 145660 145684 Wllight List Price 34 32.00 45 39.00 68 59.00 Height Weight . 14 29 18 30 24 37 List Price 30.00 35.00 37.00 23.00 23;00 35.00 LEVEL THREE Valu-Pak crate~ of tops and bottoms, not assembled, less bases & lids. Lowest unit cost/easy to handle/ships from stock. TOPS or BOTTOMS RISERS Heigth Weight 1-1/8" 9 2-1/4" 16 2"9" 32 Tops (less lids) Bottoms Less Base List Box (Components) UPC No. Lgt Wt Quantity Crate UPC No. Lgl Wt Quantity Crate AA(l OT+ 12B) 376910 lOT 1760 80 1444.00 377078 12B 1520 80 1596.00 A(16T+18B) 376927 16T 2160 60 1539.00 377085 18B 1740 60 1710.00 B(16T+24B) 376927 16T 2160 60 1539.00 377092 24B 900 30 997.00 C(16T+30B) 376927 16T 2160 60 1539.00 377108 308 1110 30 1083.00 CC(16T-36B) 376927 16T 2160 60 1539.00 377115 36B 1230 30 1311.00 D(26T+30B) 376934 26T 1530 30 1282.00 377108 30B 1110 30 1083.00 DD(26T+36B) 376934 26T 1530 30 1282.00 377115 36B 1230 30 1311.00 E (16 T + 248+#60 Ext) 376927 16T 2160 60 1539.00 377092 248 900 30 997.00 F(26T +24B+#60 Ext) 376934 26T 1530 30 1282.00 377092 24B 900 30 997.00 .... G(26T+36B+#60 Ext) 376934 26T 1530 30 1282.00 377115 36B 1230 30 1311.00 Extensions #60 Screw-Type 376989 1080 30 1055.00 Notes: To ~et equal numbers, order two crates of bottoms for each crate of tops for B, C, CC & E. Or er bases & lids separately, see above. 1-1 8-99 Tyler Pipe/Utilities Division · P. O. Box 2027. Tyler, TX 75710 · (903) 882-5511 7 . TRIM TYTE@ Ductile Iron Mechanical Joint Fittings 4" - 48" 2001 Edition For Fire Protection Water and Wastewater . GI TRIM TYTE@ Ductile Iron Mechanical Joint Fittings 4"- 48" . U.S. Pipe's TRIM TYTE Ductile Iron Mechanical Joint Fittings are manufactured in accordance with and conform to the requirements of ANSIlAWWA C 153/ A2l.53, Ductile Iron Compact Fittings for Water Service. The working pressure for TRIM TYTE Fittings, 24" and smaller, is 350 psi. For sizes 30" and larger the working pressure is 250 psi. All sizes have a surge allowance of 1 00 psi. TRIM TYTE Fittings are shorter bodied, thinner walled fittings and, consequently, weigh less than conven- tional fittings made to ANSI/AWWA CllO/A21.10, Ductile-Iron and Gray-Iron Fittings. 3 In. Through 48 In.. for Water. TRIM TYTE Tees with a flanged branch outlet are manufacturer's standard and are not in accordance to C153/A21.53 since the standard covers flanges only on 54" through 64" sizes. Fittings in the 4" through 16" sizes are furnished with PERMAFUSE$ Epoxy coating on the interior and exterior surfaces in accordance with ANSIl AWWA C 116/ A2l.l6. Protective Fusion-Bonded Epoxy Coatings for the Interior and Exterior Surfaces of Ductile-Iron and Gray-Iron Fittings for Water Supply Service. Larger fittings, except caps, plugs and sleeves, are cement-mortar lined and seal coated with an asphaltic material in accordance with ANSIlAWWA C104/A21.4, Cement-Mortar Lining for Ductile Iron Pipe and Fittings for Water. For specific conditions, TRIM TYTE Fittings can be furnished with special coatings and/or linings. Accessories (glands, bolts and standard styrene butadi- ene rubber (SBR) gaskets) are furnished per ANSIlAWWA Clll/A21.11. Rubber-Gasket Joints for Ductile Iron Pressure Pipe and Fittings. For bolt sizes see table below. Gaskets of other elastomers are available on special order for special service applications. U.S. Pipe's TRIM TYTE Fittings with fusion-bonded epoxy and with asphaltic seal-coat and cement-mortar lin- ings are listed by NSF International and conform to the requirements of ANSIlNSF 61, Drinking Water System Components - Health Effects. Accessories Size in. 4 6 8 10 12 16 20 24 No. of 3/4" Bolts 4 6 6 8 8 12 14 16 Bolt Length in. 3 1/2 31/2 4 4 4 4 1/2 4 1/2 5 Weight of Gland Bolts & Gasket lb. 8 12 14 21 25 42 51 65 . Weight of rolatable gland, bolts and gasket for 6-inch size is 15 pounds. Suggested Specification Wording Fittings shall be available in 4" through 48" sizes and shall be cast from Ductile Iron in accordance with ANSI/AWWA C153/A21.53 with mechanical joint bells. Glands, bolts, nuts and gaskets shall be in accordance with requirements of ANSIl AWWA CI53/A21.53. The working pressure for sizes 24" and smaller shall be 350 psi. For 30" and larger the work- ing pressure shall be 250 psi. At the manufacturer's option, the fittings may be coat- ed on the interior and exterior surfaces in accordance with ANSIlAWWA C116lA21.16 or cement lined and seal coated in accordance with ANSIlAWWA C104/A21.4. Fittings shall be listed by an approved certifying agency as conforming to the requirements of ANSIlNSF 61. For specific conditions, fittings can be furnished with special coatings and/or linings. TRIM TYTE Fittings are listed by Underwriters Laboratories, Inc. per EX. 2234, and Factory Mutual approved. NOTE: If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to ANSIIAWWA C105/A21.5. Polyethylene Encasement for Ductile Iron Pipe Systems for proper external protection procedures. Mechanical Joint Set Screw Retainer Glands U.S. Pipe neither manufactures, nor recommends, the use of mechanical joint set screw-type retainer glands. As an accommodation to our customers and consult- ing engineers, we do provide set screw-type retainer glands for use where specified in project plans and speci- fications. Any warranties given for those set screw-type glands sold by U.S. Pipe shall be those warranties given by the manufacturer of the gland involved. U.S. PIPE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THOSE GLANDS, AND U.S. PIPE ASSUMES NO RESPONSIBILITY FOR TIIEIR USE. Where mechanical joint retainer glands are specified, responsibility for the performance of the restraining means shall be that of the engi- neer, contractor, and/or manufacturer of the glands. TRIM TYTE@ is a registered trademark of U.S. Pipe and Foundry Co. TTM]-l . . . 11 TRIM TYTE@ Ductile Iron Mechanical Joint Fittings Bends Bends H I.U 'In it f-~r"\,\j i ~ .. f "',fI,. / 'v' "~'t$'.,_.~,." ~., ~ . oJ ,"'(.,.".".", SIZE T 900 Bend 450 Bend 221/20 Bend 111/40 Bend A Weilrht A Weil!ht A Weil!ht A Weil!ht 4 0.34 5.0 24 2.5 20 1.8 18 1.6 18 6 0.36 6.5 42 3.5 35 2.6 32 1.8 29 8 0.38 7.5 62 4.0 50 2.8 45 2.1 41 10 0040 9.5 94 5.0 75 3.4 65 2.3 58 12 0042 10.5 124 6.0 101 3.9 85 2.6 74 16 0.50 12.5 255 5.5 188 3.8 168 2.5 151 20 0.57 15.0 410 7.0 305 4.5 260 3.0 235 24 0.61 17.0 575 8.5 430 5.0 350 4.0 330 30 0.66 23.0 972 10.5 800 7.0 678 4.8 609 36 0.74 26.0 1493 12.0 1155 8.0 974 5.0 829 42 0.82 31.0 2264 14.0 1638 9.0 1368 6.0 1192 48 0.90 34.0 3067 15.0 2125 10.0 1783 6.5 1490 Dimensions in inches. Weights in pounds. TTM]-2 . . . 11",......... TRIM TYTE@DuctileIron . .... ..: Mechanical Joint Fittings .' Reducers Reducers Size T Tl L Weiaht 6x4 0.36 0.34 6.60 28 8x4 0.38 0.34 9.80 41 8x6 0.38 0.36 5.90 39 lOx4 0040 0.34 12.90 58 lOx6 0.40 0.36 10.00 59 lOx8 0040 0.38 6.90 57 12 x 4 0.42 0.34 16.10 77 12x6 0042 0.36 13.20 78 12 x8 0042 0.38 10.20 76 12 x 10 0042 0.40 7.10 74 16 x 12 0.50 0.42 5.00 112 30 x 16 0.66 0.50 30.00 644 30 x 18 0.66 0.54 28.00 669 30 x 20 0.66 0.57 24.00 613 30 x 24 0.66 0.61 15.50 533 36 x 20 0.74 0.57 36.00 987 36 x 24 0.74 0.61 24.00 779 36 x 30 0.74 0.66 15.50 664 42 x 24 0.82 0.61 42.00 1356 42 x 30 0.82 0.66 20.00 1095 42 x 36 0.82 0.74 15.50 1121 48 x 30 0.90 0.66 40.00 1823 48 x 36 0.90 0.74 28.00 1669 48 x 42 0.90 0.82 15.50 1434 Dimensions in inches. Weights in pounds. TTMJ-3 . . . 11.....-.............................-.............. : ' ' . '" '.-, .. ,.' ',' -.' ".. -. TRIM TYTE@ Ductile Iron Mechanical Joint Fittings Tees Tees I J 1 ' ! :..~ ,~ , ---_._+._.....~-..,.~.. Size Dimensions Weight Run Branch T Tl H J 4 4 0.34 0.34 4.00 4.00 32 6 4 0.36 0.34 5.00 5.00 49 6 6 0.36 0.36 6.00 6.00 58 8 4 0.38 0.34 4.50 6.50 62 8 6 0.38 0.36 6.00 7.00 75 8 8 0.38 0.38 7.25 7.25 86 10 4 0.40 0.34 4.50 7.50 81 10 6 0.40 0.36 5.50 8.00 93 10 8 0.40 0.38 6.50 8.00 104 10 10 0.40 0.40 7.50 7.50 114 12 4 0.42 0.34 4.50 8.75 99 12 6 0.42 0.36 5.50 9.25 113 12 8 0.42 0.38 6.50 9.25 126 12 10 0.42 0.40 7.50 8.75 139 12 12 0.42 0.42 8.75 8.75 152 16 6 0.50 0.36 7.50 11.50 231 16 8 0.50 0.38 7.50 11.50 235 16 12 0.50 0.42 11.50 11.50 298 16 16 0.50 0.50 11.50 11.50 327 20 6 0.57 0.36 10.00 17.00 385 20 8 0.57 0.38 10.00 17.00 390 20 12 0.57 0.42 10.00 17.00 405 20 16 0.57 0.50 15.00 15.00 525 20 20 0.57 0.57 15.00 15.00 550 24 6 0.61 0.36 7.00 19.00 420 24 8 0.61 0.38 8.00 19.00 450 24 10 0.61 0.40 9.00 19.00 480 24 12 0.61 0.42 10.00 19.00 510 24 16 0.61 0.50 15.00 19.00 675 24 20 0.61 0.57 17.00 21.00 780 24 24 0.61 0.61 17.00 21.00 800 Dimensions in inches. Weights in pounds. TIMJ-4 [!II' TRIM TYTE@ Ductile Iron m tt:chanica1 Joint Fittings . Tees (cont.) . . Size imensions Weight Run Branch T Tl H J 30 20 0.66 0.66 18.00 23.00 1030 30 24 0.66 0.74 25.00 25.00 1109 30 30 0.66 0.82 25.00 25.00 1372 36 24 0.74 0.90 20.00 26.00 1533 36 30 0.74 0.66 28.00 28.00 1604 36 36 0.74 0.74 28.00 28.00 1949 42 24 0.82 0.61 20.00 30.00 2311 42 30 0.82 0.66 31.00 31.00 2488 42 36 0.82 0.74 31.00 31.00 3063 42 42 0.82 0.82 31.00 31.00 3238 48 24 0.90 0.61 26.00 34.00 2923 48 30 0.90 0.66 26.00 34.00 3110 48 36 0.90 0.74 34.00 34.00 3979 48 42 0.90 0.82 34.00 34.00 4179 48 48 0.90 0.90 34.00 34.00 4329 Dimensions in inches. Weighls in pounds. TTMJ-5 . . . ~ li!D Sleeves Caps Size 4 6 8 10 12 TRIM TYTE@ Ductile Iron Mechanical Joint Fittings Sleeves, Caps, Plugs, Wyes ~I II! \ '!!''' 1 00 td ! III i ,-.- t [111, " r: " I' '1 i rij' lij r,.' 'l ~ '----t I ~j~~~ 'jt I &JJ T 0.34 0.36 0.38 0.40 0.42 Dimensions in inches. Weights in pounds. Wyes* Size 6x4 6x6 8x 4* 8x 6* 8x 8* T 0.36 0.36 0.38 0.38 0.38 Dimensions in inches. Weights in pounds. *UL rating of 250 psi. Weil!:ht 9 15 22 32 42 LI L2 Size T Lenl!:th Weil!:ht Lenl!:th Weil!:ht 4 0.34 7.5 17 12 20 6 0.36 7.5 28 12 36 8 0.38 7.5 38 12 46 10 0.40 7.5 49 12 62 12 0.42 7.5 56 12 76 16 0.50 15 172 20 0.57 15 255 24 0.61 15 335 Dimensions in inches. Weights in pounds. Plugs .. r ,. Size T Weil!ht 4 0.34 15 6 0.36 21 8 0.38 32 10 0.40 40 12 0.42 54 Dimensions in inches. Weights in pounds. .....;-.....'" ." .T. (0 >....l~ "'". "" ~ .....es' " ~ - f--- -~,71f>- I! rT --rll !! n .it. ~~--L.-~ I '/ ,.x/ TI 0.34 0.36 0.34 0.36 0.38 A B C Weie:ht 13.00 3.00 13.00 69 13.00 3.00 13.00 77 16.00 3.50 16.00 100 16.00 3.50 16.00 109 16.00 3.50 16.00 119 ITMJ-6 81..........". United States Pipe ... . ..." . and Foundry Company .. . . ... Goner..! 0_ .J! O. Box 10406 . Bhmingbarn. Alabama 3520' . TEL (205)254-144' . FAX (205)254-1494 . NEW . IDEAS . ARE. FLOWING. AT. U.S. PIPE www.uspipe.cominfo@uspipe.com Products for Water, Waste Water and Fire Protection Ductile Iron Pipe TYTON JOINT@ Pipe Mechanical Joint Pipe TR FLEX@ Pipe Flanged Pipe FLANGE-TYTE@ Gaskets USIFLEX@ Saltless Flexible Joint Pipe - for subaqueous installations SIZE RANGE 4"-64" Ductile Iron 4"-12" Ductile Iron 4"-64" Ductile Iron 3"-64" Ductile Iron 4"-64" 4"-48" Ductile Iron REGIONAL SALES OFFICES Restrained Joints TR FLEX@ Pipe FIELD LOK 350<1l> Gaskets TR FLEX GRIPPER@ Ring TR TELE FLEX@Assembly FIELD-FLANGE 350™ Fitting 4"-64" Ductile Iron 4"-24" 4"-36" 4"-24" EASTERN REGIONAL OFFICE (877) 663-9263 (Phone) (609) 387-6050 (Fax) WESTERN REGIONAL OFFICE (630) 920-0050 (Phone) (630) 920-0415 (Fax) PACIFIC COAST REGIONAL OFFICE (510) 441-5800 (Phone) (510) 441-5885 (Fax) SOUTHERN REGIONAL OFFICE (205) 254-7229 (Phone) (205) 254-7009 (Fax) . Ductile Iron Fittings TYTON@ Fittings TRIM TYTON@ Fittings TR FLEX@ Fittings and TR FLEX@ Telescoping Sleeves TR TELE FLEX@ Assembly Mechanical Joint Fittings TRIM TYTE@ MJ Fittings Flanged Fittings XTRA FLEX@ Coupling 14"-64" 4"-12" 4"-64" INTERNATIONAL SALES OFFICE (205) 254-7230 (Phone) (205) 254-7274 (Fax) 4"-24" 4"-48" 4"-24" 4"-64" 4"-24" WASTEWATER PRODUCTS SALES OFFICE (205) 254-7264 (Phone) (205) 254-7174 (Fax) Miscellaneous Products PROTECTO 401 Lined Ductile Iron Pipe for Domestic Sewage and Industrial Wastes Polymeric Coatings and Linings Saddle Outlets Welded Bosses Welded Outlets Polyethylene encasement (8 mil and 4 mil cross laminated Polyethylene loose wrap - field applied for external protection in corrosive environments) 4"-64" For all pipe sizes Various Various Various For all sizes Valve, Hydrant and Tapping Products for the Water Works Industry Fire Hydrants - 4 1/2" and 5 1/4" sizes, AWWA, standard and high pressure type. Resilient Seated Gate Valves - 3"-16" METROSEAL@ 250 RlS Valves, AWWA C509, Also 18" through 36". Double Disc Gate Valves - 3"-60", AWWA C500. Tapping Sleeves and Valves - All sizes. Inserting Valves - 4"-20" Tapping Machines - Taps 4" -16" and larger, available for sale. BRO-015 . 8"0l WEB . 8M PE FUSE@ Epoxy Coated Ductile Iron Fittings . u.s. Pipe's TRIM TYTE@ and TRIM TYTON@ Fittings are now available with our METRO SEAL @ Valve tested PERMAFUSE@ Epoxy Coatings . United States Pipe and Foundry Company General Office · P. O. Box 10406 · Birmingham, Alabama 35202 · TEL (205) 254-7442. FAX (205) 254-7165 www.uspipe.com email: marketing@uspipe.com . ">>:"'<:;: NEW. IDEAS. ARE. FLOWING. AT . U.S. PIPE Features and Benefits of u.s. Pipe's PERMAFUSE@ Epoxy Coated Ductile Iron Fittings: · Mechanical Joint and TYTON@ Fittings, available in sizes 4"-16", in accordance with ANSI/AWWA C153/A21.53 · PERMAFUSE Epoxy Coatings meet or exceed ANSI/AWWA C550 and Cl16/A21.1I6 requirements · NSF 61 approved for drinking water service · Nominal coating and lining thickness 6-8 mils · Larger sizes, flanged fittings and AWWA ClIO fittings with PERMAFUSE available upon request . ...,) . PERMAFUSE Epoxy Coatings are tightly adherent, provide a smooth surface and can be applied to inside and outside surfaces · PERMAFUSE Epoxy Coatings have been used successfully for many years on resilient seated gate valves · Suitable for water and many wastewater applications Suggested Specification Wording Ductile iron fittings shall be coated with a 6-8 mil nominal thickness fusion bonded epoxy conforming to the requirements of ANSI/AWWA C550 and CI16/A21.I6. MINNESOTA PIPE & EQUIPMENT 5145 211th Street West · P.O. Box 249 FARMINGTON, MN 55024 651-463-6090 651-463-4554 Fax 800-325-5636 . BRO-081 . METROSEAL@ 250 Resilient Seated Gate Valves 3"-16" For uateJ; uastewateJ; Fire Protection and Industrial Applications 2001 Edition . . . HI METROSEAL@ 250 Resilient Seated Gate Valves 3" - 16" INTRODUCTION The 3"-16" METROSEAL 250 Valves featured in this publication are rated at 250 psi. They conform fully to ANSI/AWWA C509 Resilient-Seated Gate ~Jves For f.%ter Supply Service and ANSI/AWWA C550 Protective Epoxy Interior Coatings For ~Jves And Hydrants. The body, bonnet and gate are Ductile Iron, instead of gray iron (3" gates are bronze) . TYPICAL APPLICATIONS FOR METROSEALREDUCED WALL VALVES General METROSEAL 250 Resilient-Seated Gate Valves are designed for use in virtually any type of buried or above-ground service for water transmission or distribution lines, sewer force mains and certain types of industrial service within the operating pressure range of the valve. The greatest use is in buried service where low cost, positive and reliable shutoff and minimum maintenance are important requirements. Resilient Seated Gate Valves generally operate fully opened/fully closed, although METROSEAL 250 Valves may be operated in the throttling mode when required. Buried Service METROSEAL 250 Valves are designed for buried service. It is not necessary to install them in a vault or manhole as is appropriate for other types of valves where maintenance is required and frequent repairs may be necessary. Years of experience have demonstrated that resilient-seated gate valves rarely require maintenance and are typically buried underground without the need for access. Buried valves are normally installed in the vertical position and actuated through a standard valve box by a T-Handle operating wrench (or power operator) which engages the 2" square operating nut. For shallow depths of cover, 16" valves may be installed in the horizontal position and activated through a bevel gear unit mounted on the valve. Buried service valves are specified with mechanical joints or TYTON ]oint@ Pipe when used with pipe having Ductile Iron pipe outside diameters. - . . . HI METROSEAL@ 250 Resilient Seated Gate Valves 3" - 16" Interior or Above Ground Service METROSEAL 250 Valves with flanged joints are used for this type of service, particularly in water and sewage treatment plants, industrial use, pump stations, meter pits, etc. Flanged valves are furnished with ANSI/AWWA C115/A21.15 standard flange drilling, which will also connect to ANSI/AWWA C207 Class D steel flanges and ASME BI6.1, Class 125 flanges. Flanged gaskets 1/8" thick should be used. U.S. Pipe's FLANGE-TYTE@ Gasket is recommended. The METRO SEAL 250 Valve is suitable for any position of installation: vertical, horizontal, flat or angled. If sediments are present, care should be taken that the bonnet is not in a position to collect sediments which could interfere with operation of the valve. Gear operators can be rotated as required. VALVE GEARING METROSEAL 250 Valves operate with considerably less torque than double disc metal-seated gate valves and may be operated without gearing at normal operating pressures. It is recommended you consult with our Valve and Hydrant Sales Office if gearing is specified. When specified, valves can be supplied with bevel gearing. Gear operators are the totally enclosed type, oil filled and designed for buried and submerged service. Gear housings are Ductile Iron. Gears are steel and pinion shafts are stainless steel. Shaft bearings are Teflon with "0" Ring seals. NO. NO. NAME OF PART re d. 12 PIN 1 20 GEAR BOX EBG 1 21 PLATE GEAR EBG 1 22 OPERATING NUT 1 23 GEAR, BEVEL EBG 1 24 GEAR PINON EBG 1 25 SHAFT PINON EBG 1 26 BEAR I NG SHAFT 2 27 KEY PINON SHAFT 1 28 WASHER, THRUST 1 29 WASHER ANTI.FRICTlON 2 30 RING, RETAINER 1 31 PIN OPERATING NUT 1 32 O.RING SHAFT 1 33 O.RING GEAR BOX 1 34 O.RING GEAR PLATE 1 35 O.RING SCREW SEAL 4 36 BOLT, HEX HEAD 4 37 BOLT HEX HEAD 6 38 NUT HEX 6 39 HANDWHEEL, EBG. OPTIONAL 1 - MATERIAL STEEL DUCTILE IRON DUCTILE IRON CAST IRON STEEL STEEL STN. STEEL TEFLON STEEL BRASS THERMOPLASTIC STEEL STEEL RUBBER RUB8ER RUBBER RUBBER STEEL STEEL STEEL DUCTILE IRON GI Dimensional Charts . NO. DIMENSION DESCRIPTION NOMINAL VAALVE SIZE 3" 4" 6" 8" 10" 12" 18" A Bonnet Flange Length 8-3/8 9- 13/16 13 15-5/8 19-7116 21-1/8 25-5/8 B Handwheel Diameter 10 10 12 14 16 16 23 C Waterway Diameter 3-1/32 4 -1132 6-1/8 8-1/16 10-1/8 12-1/8 16-118 D1 Mechanical Joint Bolt Circle 6-13/64 7-1/2 9-1/2 11-3/4 14 16-1/4 21 D2 Flanged Bolt Circle 6 7-1/2 9-1/2 11-3/4 14-1/4 17 21-1/4 E Bonnet Flange Width 4-1/8 7-1/4 8-3/8 9-5/8 10-15/16 11-1/16 13-5/8 F Face-to-Face (End to End) Mechanical Joint 8-1/2 9-1/4 10-1/2 11-112 14-1/2 15 22 Flanged, Face-to-Face 8 9 10-1/2 11-1/2 13 14 16 Mechanical Joint X Flanged & Mechanical Joint X Flanged Tapping 8-112 9-3/32 10-3/4 12-1/2 13-3/4 14-1/2 19-112 TYTONe Valve N/A 11 12-3/8 14 14-3/8 14-718 23 TYTON e X Flanged Valve & TYTONe X Flanged Tapping Valve N/A 10-5/16 11-7116 13-1/16 14 14-3/4 N/A G Flange Diameter 7-1/2 9 11 13-1/2 16 19 23-1/2 H Tapping Flange Lip Diameter 3-63/64 4-63/64 6-63/64 8-63/64 10-63/64 12-63/64 16-15/16 J Tapping Flange Lip Height 3/16 3/16 1/4 1/4 1/4 1/4 1/4 K Body-Bonnet Flange to Centerline of Waterway 5-27/32 6-5/16 8- 19/32 11-1/4 13-1/4 15-11/16 19-11/16 L Top of NRS Nut or Handwheel to Center of Waterway 10-1/2 12-13/16 16-1/4 19-3/16 24-1/2 27 -5/16 34-3/8 M Top of OS& Y Stem to Centerline of Waterway Valve Closed N/A 18-13/16 25-5/16 30-118 38-3/4 41-5/8 55-1/8 Valve Open N/A 23-3/8 32-1/16 38-3/4 49-1/2 53-7/8 71-3/8 N Number of Turns to Open (NRS & OS&Y) 13-1/4 13 19 25 32 37 50 P Maximum Tap Size (Optional) 1/2 1/2 3/4 3/4 1 1 1 S Depth of Socket Mechanical Joint Socket 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3-5/8 TYTONe Valve Socket N/A 3-1/2 3-1/2 3-3/4 3-7/8 3-7/8 5 . . - gg Part List . . 2 17 13 1 3 t NON-RISING SfEM NO. NO. NO. NAME OF PART re d. MATERIAL NO. re d. MATERIAL 1 BODY 1 DUCTILE IRON 10 1 THERMOPLASTIC 2 BONNET 1 DUCTILE IRON 11 1 RUBBER 3 GATE RUBBER COVERED 1 DUCTILE IRON 12 1 STEEL 4 STEM 1 BRONZE 13 1 RUBBER 5 STEM NUT 1 BRONZE 14 1 RUBBER 7 OPERATING NUT 1 GRAY IRON 15 2 RUBBER 8 CARTRIDGE 1 THERMOPLASTIC 16 STAINLESS STEEL 9 BONNET TRUST WASHER 1 THERMOPLASTIC 17 STAINLESS STEEL . - 8M . METROSEAL@ Resilient Seated Gate Valve 3" - 16" . . Directions For Ordering 1. The quantity required 2. The size or outlet diameter 3. The body configuration: FIG. # 5460 5150 5860 5260 5080 BODY CONFIGURATION Mechanical Joint Valve Flanged Valve MJ x Flanged Tapping Valve MJ x Flanged (Non-Tapping) TYTON@ Valve FIG. # 5160 5220 5940 5120 BODY CONFIGURATION TR FLEX<I> (16" Only) Valve TYTON x Flanged Valve TYTON x Flanged Tapping Valve Flanged OS& Y Valve Stem material Standard stems are manganese bronze. Low zinc bronze stems are available on special orders where water may cause dezincification. Direction to open Valves are furnished open left and the operating nut is painted black - open right valves have operating nuts which are painted red. Operators Type of gearing if operating nut or handwheel required: Spur or Bevel Accessories Mechanical Joint Valve Ends Mechanical joint ends of METROSEAL 250 Valves are furnished with glands, SBR rubber gaskets, tee-head bolts, and nuts unless otherwise specified. Flanged Valves Flanged valves are furnished with FLANGE-TYTE@ Gaskets when requested. Flanged connections require the use of a lI8-inch thick rubber gasket. Tappini Valve Flaneed End The tapping flange of a METROSEAL 250 Valve is furnished with bolts, nuts and a special gasket. TYTON Valves TYTON Valves are furnished with TYTON@ Gaskets or FIELD LOK 350@ Gaskets can be specified where joint restraint is required. Bolting METROSEAL 250 Valves are furnished with stainless steel bolts and nuts. REFERENCE DRAWINGS Detail drawings suitable for submittal purposes may be obtained from your local U.S. Pipe sales office or the Valve and Hydrant products sales office in Chattanooga, Tennessee, Telephone 423-752-3700, Fax 423-752-3710. 4. 5. 6. 7. 8. CAUTION: Neither push-on products assembled with TYTON@ Gaskets nor mechanlcaljoint products assembled with standard accessories as detailed in ANSII AWWA C 1111 A21.11 provide any degree of restraint against joint separation. While the configuration in which such products are assembled may in and of itself offer some degree of such restraint, our push-on joints with TYTON Gaskets or mechanlcaljoints with standard accessories provide ABSOLUTELY NO RESISTANCE TO JOINT SEPARATION. The user must either ensure that restraint is not needed when using our push-on or standard mechanical joint products, or, if there is any question, he must consult a qualified engineer. If the application to which a push-on joint product is being placed requires restraint, U.S. Pipe recommends the use of FIELD LOK@ Gaskets or TR FLEX@ Pipe, Fittings or Valves-consult with your local U.S. Pipe representative. For mechanlcaljoint connections, various restraint devices are available and the user should consult their manufacturer. - . . 11 United States Pipe and Foundry Company Valve and Hydrant Products. P.O. Box 6159. Chattanooga, TN 37401 .. PHONE: (423) 752-3700 . FAX: (423) 752-3710 www.uspipe.com NEW - IDEAS - ARE- FLOWING -AT-U.S. PIPE email: lnfo@uspipe.com u.s. Pipe Valve and Hydrant Products for the Water and Sewage Industry Fire Hydrant: Dry Barrel, both post and flush type; standard and high pressure. METROSEAL@ Resilien Seated Gate Valves: 3- through36-inch, both non-rising stem (NRS) and out- side screw and yoke (OS&Y). Double Disc Gate Valves: 4- thorugh 50-inch, manually and power operated, in all popular configurations. Standard and high pressure. Tapping Valves: Available in Resilient Seated or Double Disc styles. Tapping Sleeves and Tapping Saddles: For all popular sizes of Ductile Iron, gray iron, steel or concrete pipe. Contact nearest sales office for details. Tapping Machines: 4" - 16" taps on all types of pipe. Contact nearest sales office for details. Underwriters Listed and Factory Mutual Approved: Fire hydrant and valves, for standard and high pressure. Valve and Hydrant Sales Valve and Hydrant Sales Tel: 877-811-2537 2500 Chestnut Street Chattanooga, TN 37408 R.C. "Bob" Grueter, Sales Manager, V&H Products Tel: 423-752-3701 Fax: 423-752-3710 G.L. Hartman, District Sales Manager. V&H Tel: 423-752-3702 Fax: 423-752-3710 Territory: GA, NC, SC Michael D. Cole Tel: 972-935-0330 Fax: 972-935-0450 Territory: TX, OK, LA, and AR Andrew Podner Tel: 931-358-9152 Fax: 931-358-9153 Territory: East TN and KY (except northern counties) Samuel W. Williamson Tel: 610-566-7915 Fax: 610-566-7865 Territory: PA, NY (including NYC & Long Island), \IN Kevin B. Kempton Tel: 609-714-3300 Fax: 609-714-6870 Territory: NJ, DE, MD, VA, DC Chris MacDonald Tel: 816-741-3022 Fax: 816-746-4246 Territory: KS, MO, NE Our specialized experience in this field since 1896 is available for the solution of unusual engineering problems. Please contact us at 423-752-3700 or www.uspipe.com on the web. FAX 423-752-3710. . BRO-046 DISTRIUBUTED BY U.S. PIPE VALVE & HYDRANT PRODUCTS 9/01 web . . . ~ ~~~[t)~ ADJUSTABLE EXTENSION STEM PAINT SP!:CS 4" SOl 40 Pqx; I" Lont' :2" x 2" x 3/16" Square Tubing 7" Long il..cM ".ROMII'\' MalOI Pnfl1IJIIS IJ IUS/lonIOllIV!! leOOllee ;1l1:",IJ. ).;f)OSt: !Tl~IQI91Imel tOl use os DOlIi on Inlell- ,jr ,~\,....: ~l:~' ":;1 ;)f:r1cl Of, O€lon Ot OiQSf&C Sleal II con oe ..;~"'.: :~ .: ),')O~, :C\J: or f'.;lie '~OCl! II JIII1~ IOS! l.lI\OvQ" ''Ie' i "'\>( A :Qjj.::Oo;luC r,le sorna 0(.''1' l.'1v~ m.n.rnlllrlQ "'l;: :::;'1""."0:' UiIQ:,Gv' 'f ?!c.'~'oes ij~Ct'!leI'10,,1001"r.., J~ .. ~.' . ( ,r" '..J' ~ : ',,<: ;J I ,I ", t: 1/2" X 13 xl" Hex Head Crade 5 Plated Cap Sere\\ CHARACTERISTICS . ,n:~~ ;.(; )IJ M&QI R~~ISlonce ?OO"t 'Jlflll" S<:fitiQOJll) (\emp8/0l\ir8 & numlOl1'y O&pafioenl), 'Vn'~ one ')0'). R" ;> "tll;! ;' '')V\';' ,.,;: ~....;' " ~'Ov' ; 'i:~!' P'J,rl ~'O; '-f::'~'i M\,)f1er'15 :;'(')0;;(' . _. ii.tlc~mme"c\jc Spl&OOlni; ROle "'~, "'''15 6 J 9 C .:r, """5 2) J ~ ;':~'.I;~ ')C "~c: 8';?'Jt ,.,Oll :).' _sr Oi !Qil G;:>o"C(;llon mOr 'eQ,,"ij ml,;II.~'~ ~.:-:~s I( J(""~Yll fT"Io~,m\.l(n 1i11T". !fllc~n~S5 Or\C v!'lIrO'IT), ~, ), ~~t~,~.:;. :-')~'i:i SURFACE PREPARATION -:."'[::.:~ ""',,5' :;.tl :JI~ DnQ ,r; 50vr.a -:Or.OilIOr: lielTlove :,:.. .;,:' IOC'';,,:: l'~sr ~bl'l1<,; ;x};nr Or Olner conlom,rlOllor. Ie .n:,;' t -rJ'~ Qor'eSIOI' IfJn ,Jnc S:i:iji ~Ol 'TIC.l.;nlJ~ O',;i00111l'r Ji :-:jII1f 5Y511;rT' ~'t"~Ii! T.t )~l;lt'j!(II ,r. OCCOIOQi',Ce ....I!!' SSP<: 1/2"\ 1 ]2"\3 16 Sq. Tubint' >1.: :'0"..! e'~ (:, ciC5i M,r. rr;Ol" ~-,J':J':i: : c~,,;::',~1 }'":(,;.'<'; ':it' .'1C 'ass !{';c:\ sSPC S?; ....(;"C >-^~ .'.t'-':- ,(',.; ')o5S;:><: S;;j ;;'..M-t:1 'x., ':'tC""n~' ~'e,'0",S:, f-OllllltC fellOWS $;;r10ces 'I ,n so.;'".,,) Ciroe, ;ltl,,'J" "'e S.;r1cce Or 'Jll10lelgn IT\Cle!IQ: :1 ?(l,nt I~ :>:a,"';:; :'CC',....l!QI'1l!reC C'i!cn $"I:(;(E- ': ~(),;":: :;~~'<,"ctt' ji,C t'llCiI:;:. C :"\I;v.- Svr10Ct cm~ T!'"lf S""<""''''''l'Illl~jT"\, ComD~("l\< :'\I>"'j -'(1 .41' ~ .____IE~!!!!!!!._~ tllt~t ,1", 10 POI) ""~I :~I,,~m lJfOO(\~:t ,'O~ OllOf Sel~ml( ,4':'lm(lflYlcel'erlt , J ).TlimunYIIXI\~fl~ ~:nYIDf~:ffl~ I,ll '_IQnlAJDlTlali(I1'1'OIOCartIOfl\ iQ~;491 QmYl.' 1\IO$lQol __~MICALlY RlACTlY( Bottom Socket 2"x 2"\ 3/16" Sq .rube J ,(lnt' \FlEDVflABRl A.l'O \, c\\S 'tfJ' \ '\ y ~ ~y. \)\ l' -- . J - 1/2",< 13" 1" lk" Ileac! Grade 5 Plated Bolts ./ ')il Rt 4 Box 87B Pine Clly, MN 5506J (J20i 629,5479. FAX 629.5479 "" CIClr$nC9 &. Amino. 'fy'imm., Boo 6. Jaf'l9 JOf1e1 ;" .; . . I II-I I . L-L-. L-II:..lV.L L- - .-'.a.1 I I 2300 E. 25TH ST MPLS, MN 55406 Phone: 612-728.3507 Fax: 612-728-2500 Fax 1'0= MN Pipe and Equipment Attn:Brlan Graybar Electric From: Scott Olson Fax= Date: May 22. 2001 Phone: '-0..: 3 cc; Re; l:I U.,..nt X For R8v1ew o Pi.... Co",,,,ent D PI__ Reply o Pi.... Recyde -Comm.nts; Thanks . . . Iln I. '-'-_ t...1U1U.L t.... ........1.1 I I Copper Building Wire THHN 600 Volt. Copper Conductor. TJ,e,moplastic Insulation/Nylon Sheath. Heat, Moisture, Oil & Gasoline Reahstant1. All Sizes Rated THWN..2. All Stranded Sizes Rated ",TW. AWG Sizes 14 Th,ough 6 AWG "ated AWM (105DC). AWG Sizes 14 T~"ou9h 1 Jlated VW..1 and Larger Sizes Rated for CT Use. G~ ( APPLICATIONS Southwire TYPe THHI'I or THWN-2 conductors are primarily llsed in cond\.lit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code2. When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 9000, When used as Type THWN-2, conductor Is suitable for use in wet or dry locations at temperatures not to exceed 9000 or not to exceed 75"0 when exposed to oil or coolant. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 600C or dry locations at temperatures not to exceed 90DC (with ampacity limited to that for 750C conductor temperature per NFPA 79). Conductor temperatures not to exceed 10500 in dry locations when rated AWM and used as appliance wirIng material. Voltage for all applications is 600 volts. SPECIFICATIONS Southwire Type THHN or THWN-2 or MTW (also AWM) meets or exoeeds aU applicable ASTM specifications, UL standard 83, UL stE;\ndard 1063 (MTW). Federal Specification J-C-30B, and requirements of tM National Electrical Code. CONSTRUCTION Southwire Type THHN or THWN-2 or MTW copper conduotors are annealed (soft) copper. insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC). over whioh a nylon (polyamide) or UL~listed equal jacket is applied. Available in black. white, red, blue. green. yellow, brown, orange, or grey. Some colors standard. some subject to economic order quantity. Sizes '~'9 through 1,000 kcmi! available In black only. 1 011 and gasoline reeletanc:e If M deflrll~d py Um:lGtwrllers Laborator[es. · 1 9S6 EdlliOn. <0 Southwire rrt\ M~.g: \!!,J USA CQ~yrlg1'lt 1 BB5, Soulhwlra CDmpany. Alll'llllnla RaaalVad. * Prll'llo~ on Reeyelecll"aper ;..1 JHHN Conductor Nominal Approx. Net Allowable Insulation Jacket 0.0. Weight Per Ampacitie$+ Standard Slm No. ThickneSG Thickness (mils) 1000' (Ibs.) Packllge (AWG Dr Strands (milS) (mils) 60.0 750C 90'C kcmll) Sol. Srr. Sol. Stt. "14 1 gw 15 4 102 109 16 16 15 15 15 ONFo --12 lB- 15 4 119 128 23 24 20 20 20 ONFo .-10 19~ 20 4 150 161 37 sa 30 30 SO OOF" -a 19 30 S 212 63 40 50 55 F "'6 19 30 S 250 95 55 as 75 5 4 19 40 6 319 153 70 S5 95 C 3 19 40 6 346 1B9 66 100 110 80 2 19 40 e 378 234 95 115 '30 C 1 19 SO 7 435 SOO 110 130 150 B 1/0 19 50 7 474 372 125 150 170 B 2!0 19 50 7 518 463 145 175 195 B 3/0 19 50 7 sea 676 165 200 22S e 4/0 19 SO 7 , 624 719 HIS 230 260 B 250 37 60 8 694 849 215 255 290 El SOD 37 60 B 747 1010 240 285 320 B 350 37 60 6 797 1172 260 310 350 B 400 37 60 8 842 1332 280 335 380 B 500 37 60 B 925 1652. 320 380 430 B 600 61 70 9 1024 1990 355 4.20 475 C 750 61 70 9 1126 24Q8 400 475 535 C 1000 61 70 9 1275 3263 466 545 616 C . IOond llQI1.$InJOtlOl'l av8ll8lll9 In ab:~ 14, 12, & 10 &II Types TH"'''' or "floIWNol! or AWM only. Sl'ANClAFlP PACKAGr: CODe: \wlIlll,lilab\e fer 105"0 appllill1C9 wiring melel1al (AWIIl), 1:1" 1000' AseI ~our 600' 6pOOI& per carlllll. C = Soo' flqol 'Two 500' Bp<lO~ por 1l~f1c(l. p . 2600' 5pl101 + AIIoWl\bk> "rnp~cl~e8: j; .. 1000' Spool AIIQ~p\lllltTlpacl~811 ahDWn l1('O Illr general use Ill! apoclffod by IllS NalJonst elaclrlcnl Cllda, I' = 500' Spool lB96IOd\~Dn, sactlClf13,O.15. N .. 2000' ~tUl" 8O'e. Wt)Qn lalTlllnaf8d!Cl equt!j!~t f1;lr 1lirll4~B 1'lWl~ 100 amfl'lF1l5 or IIlSIl or ma~cI for "4 Q .. 2IlD' Canon t~(()Ullh 1/1 cOl1llllClO~. wet IllC8Ilons or Whllll e><po&8d 10 DR or caolilnt, 75"C. W118I11OOT11ngtrld 10 equlpI!\Sm1ar c1l'C\lil; ral6d Oller 100 1lmpsf811 or 1JlIIrl<<!d for ClElf1Cl4OIllrs Iafosr 1I1all it,. THWN-2 whe~ llICpOlI8lllV 1111 ar oootanl. MTW dry lacajlDr\a. BO'C . THHi"l dly IaOallOllB. THWN.2 \WI QI" dI'f 1OCatI0I)S. ~I AWG eiZ8814 Jh/llllgll 1 !1lrcd vw.,. Larger elzea IiIlG1d lor C'f Use. Cl11195 ~. " RECOMMENDED SAMPLE SPECIFICATIONS: (MTW OR THHN OR THWN-2) Conductors shall be UL.listed Type M1W or THHN or THWN-2 gasoline and 011 resistant II, suitable for operations at 600 volts as specified in the National Electrical Code. AWG sizes 14 through 1 $hllll be rated VW-1 . larger sizes shall be rated for CT use. Conductors shall be annealed copper. insulated with hlgJ1.heat anq moisture resistant PVC, jacketecl witt! abrasion. moisture, gasoline, and oil resistant nylon or UL .listed equivalent, as manufactured by Soutl1wire Company or approved equal. (AWM) Conductors shall ~e UL-Iistad Type THHN or THWN-2 or MTW or AWM, suitable for operation at 600 volts at conQuctor temperatures not to exceed 1050C. . o Soutbwire 1 RD. Box 1000 Carrallton. GA USA 30119.0001 77O/B32-4~42 CONSTRUCfION AMERICAN FLOW CONlROL A 5-1/4" PACER FIRE HYDRANT . TRAVEL STOP NUT-Provides a positive limit to main rod travel. lWO PIECE OPERATING NUT-Ductile _~ iron upper section provides strength for wrenching. Lower portion is bronze for smooth operation and corrosion resis- tance. 360. NOZZLE SECTION ROTATlON- The Waterous stainless steel retaining ring system allows 3600 rotation by merely loosening the flange bolts, and tumlng the nozzle section to the exact position desired. ~ MECHANICALLY ATTACHED NOZZLES- Field replacement of damaged noz- zles In minutes by one person. . -~ CENTRIFUGALLY CAST DUCTILE IRON BARRELS-Stronger, smoother and more uniform than static cast barreis. TRAFFIC SECTION-Parts are designed to break at the ground line. Simple iow cost repair kit available. ALL BRONZE DRAIN-No composition, plastic, rubber or leather face to wear, ~ peel or crack. ~ FLAT BOTTOM AND STRAPPING LUGS- All standard to make solid, straight "- Installation faster and easier. '" ~ '~ "- 1L1387 ~ BRONZE TO BRONZE SEATlNG-O-ring protected bronze valve seat threads into a bronze insert in the hydrant bot- tom. INTEGRAL CAP NUT AND LOWER WASHER. Protects rod threads from cor- rosion and makes servicing easy. Valve assembly locked In place. It cannot detach accidentally. Fully complies wlth AWWA C.502 and is available In configurations which are UL Listed and FM Approved. . 1 SECl10NAL DRAWINGS/DIMENSIONS . AMERICAN FLOW CONlROL A 5-1/4" PACER FlRE HYDRANT OPERAllNG NUT 2-1/2 IN. HOSE CONNECTION (THREAD SIZE:_ 0.0. X _T.P.I.) 3 IN., 3-1/2 IN., 41N., 4-1/2 IN. OR 5 IN. PUMPER CONNECTION (THREAD SIZE: 0.0. X _T.P'!.) BOTTOM, 6 IN. MECHANICAL JOINT SHOWN NOZZLE SECTION 8-318 4-314 J UPPER STANDPIPE 18 NOMINAL GROUNDLlNE GROUNDllNE GROOVE . BURY 1'-6" THRU 11'-6" DEPTHS AVAILABLE 8-318 DIA lOWER STANDPIPE 1 ~T 3-318 IL1387-1 2 OPTIONAL ROCKER LUG CAP 6" BOTTOM 11-1/4 I End Connection L M N Flanged 8-1/4 11 6 Mechanical Joint 7-13/16 10 7-1/32 Tyton 9-1/16 8-21/32 7-1/32 PVC 9-11116 8-9/32 6-3/4 8" BOTTOM End Connection L M N Mechanical Joint 9-5/8 12 9-3116 (6) 7/8 DIA HOLES EQUAllY SPACED ON 9-1/2 BC 12-1/4 ==rl dJ LL~ . FLANGED CONNECTION MECHANICAL JOINT CONNECTION 2 TYTON JOINT CONNECTION PVC JOINT CONNECTION FEATURES/BENEFITS SPECIFICATIONS . FEATURES The Waterous Pacer's sleeK and stylish design blends perfectly with today's modern architecture. The Pacer is rated for 250 p.s.l.g. and exceeds all of the requirements of AWNA C-502. Ductile Iron construction assures strength and durability. Introduced in 1967, the Pacer fire hydrant provides real solutions to AMERICAN FLOW CONTROL A 5-1/4" PACER FIRE HYDRANT today's system demands. With many cities experiencing Increased pressure to stretch their dollars it Is important to note that the Pacer hydrant can be maintained by just one person. The remaval of four nuts and bolts allows access to all working parts. The Pacer hydrant is loaded with all of the fea- tures expected from a high quality fire The Pacer hydrant has these standard features: . All bronze drain . Travel stop nut located In top of hydrant . Easy 3600 rotation of nozzle section BENEFITS . Easy Nozzle Section Rotation The Pacer's exclusive stainless steel flange locK ring allows 360 degree rota- tion of noZZle section by merely loosen- Ing four bolts and turning nozzle section to the exact position required. This is done without damage to barrel gaskets. Sealed Lubrication Chamber O-rings seal the operating threads from moisture and retain lubricant which greatly reduces routine maintenance. SPECIFICATIONS . Fire hydrants shall meet or exceed AWNA C502, latest revision. Rated work- ing pressure shall be 250 p.s.l.g., test pressure shall be 500 p.s.l.g., and hydrants shall include the following specific design criteria: The nozzle sectiOn, upper and lower stand pipes and hydrant base shall be ductile Iron. The main valve closure shall be of the compression type, opening against the pressure and closing with the pressure. Nozzle section to be designed for easy 360 degree rotation by the loosening of . 250 p.s.l.g. working pressure ral- ing . Shelllested at 500 p.s.l.g. . Sealed lubrication chamber . Over 30 years of continuous All Bronze Drain No composition rubber, plastic or leather to wear, chip or cracK. Virtually no leaks, ror adjustments are ever required. Bronze sliding drain valve Is free to center itself so it always closes tightly, even if a foreign object gets Into the barrel. Top Travel Stop Nut Helps prevent stem bucKling and damage to bronze components. no more than four bolts. The seat diameter shall be 5-1/4". Hydrant must be designed so that removal of all working parts can be accomplished without excavating. The bronze seat shall be threaded Into mat- ing threads of bronze for easy field repair. The draining system of the hydrant shall be bronze and be positively activated by the main operating rod. Hydrant to be furnished with a sliding bronze drain valve. Sliding drain valves made of rubber, plastic or leather will 4 hydrant. The all bronze seat and bronze seat insert assure that the Pacer hydrant remains easy to repair. The Pacer has been manufactured for more than 30 years while still main- taining complete parts Interchange- ability. paris Interchangeability . Ductile Iron nozzle section, upper" lower stand pipes .. hydranl base . Bronze-Io-bronze seating . Bronze cross arm not be allowed. Hydrant must have an Internal travel stop nut located In the top housing of the hydrant. Hydrant operating threads to be fac- tory lubricated, and be O-ring sealed from water, moisture and foreign matter. Hydrant must have a traffic flange design allowing for quick and economi- cal repair of damage resulting from a vehicle's Impact. Hydrants shall be Waferous Pacer. (Model number WB-67-250). ~