Loading...
2000-10-30 MN Dept of Health Report on Plans OCT-30-2000 11:58 E.G.RUD & SONS INC 612 786 6007 P.06/07 MINNES01/\ DEPARTMENT OF HEALTH Division of Environmental Health REPORT ON PLANS Plans and spec?.fi.cations on watermain: Albert Villas Third Addition, Albertville, Wright County, Minnesota. Plnn No. 0 llO~6 OWNERSl-DP: City of Albertville, c/o Ms. Linda Goeb, Clerk, Albertville City Hall, P.O. Box 9, Albertville, Minnesota 55301-0009 SUBMITTER(S): Plowe Engineering, Inc., 9180 Lexington Avenue Northeast, Circle Pines, Minnesota 55014 Plans Dated: . Date Jkceived: S-ept~~er 28, 4Q()O._ -- Date Reviewed: October 23, 2000 .., SCOPE: This report coverS the design of this project insofar as the safety and sanitary quality of the water for public consumption may be affected, and applies to this project only and not to the entire system or any other part thereof. The examination of plans is based upon the supposition that the data on which the design i$ based are correct, and that necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features and the efficiency of equipment must be taken by the project designer. Approval is contingent upon satisfactory disposition of any requirements included with this report. Water supply plans are examined with regard to the location, construction :tnd operational features of the design and maintenance of all parts of (he system which may affect the safety and .sanitary I~uality of the water. Examination is based on the standards of this department. This project consists of the installation of the following watenrlains: 1. 176 lineal feet of 6-inch ductile icon wateonain. 2. 1,135 lineal feet of 8-inch PVC plastic watermain. -i~";"~ "~c~'"'3::'3;082innea[red Of 1. O:inchPV C plastic watermain.----- ---- - --..~ .- REQUIREME;NT(S): L It is underswod that the installation will be.in accordance with previously approved specifications (City Engineers Association of Minnesota. 1988 edition), as modified by the Special Provisions and Standard Detail Specifications. 2. It appears tbat the separation distance may be less than 10 fet:t between the fire hydrant and storm sewer Manhole A. Please verify, here an elsewhere, that the hydrant drains shall not be connected to or located within 10 feet of sanitary sewers or storm drains. 3. Please note that the future watermain crossing of County Ditch Number 9 along Kagan Avenu~ may need to consider th,~ requirement that a minimum cover of 2 feet shall be provided over the pipe for underwater crossings. When crossing water courses which are greater than 15 feet in width, the following shall be provided: 10/30/00 MON 14:41 [TX/RX NO 8142] OCT-30-2000 11:59 E.G.RUD & SONS INC 612 786 6007 P.07/07 - ,..... Abert Villas Thjrd Addition Watermain Plan No. 011086 Page 2 October 23,2000 a. The pipe shall be of special CODStIUCtiOD) having flexible watertight joints. b. Valves shall be provided at both ends of water crossings so that the section can be isolated for testing or repair: the valve;; shall be easily accessible, and not subject to flooding; and the valve closest to the supply source shall be, in a manhole. c. Penmment taps shall be made on each side of the valve within the manhole to allow insertion of a small Deter to determine leakage and for sampling purposes. COMPUANCE: No construction shall take place'except in accordance with the approved plans. If it is desired to make deviations from the approved plans, the State Department of Health should be consulted and approval of the changes obtained before construction is statted; otherwise, such construction is installed without proper approval, and in addition may create dangers to public health. Authorization for construction in accordance with the approved plans may be withdrawn if construction is not undertaken within a period of two years. The fact that the plans have been approved does not necessarily mean that recommendations or requirements for change will not be made at some later time whim changed conditions, additional information, or advanced knowledge make improvements necessary. Approved: \'~'-~\l C . . .\ k 1, 1,..i.N.)!\.. hn F. Carney .~ Public Health Engineer Section of Drinking Water Protection P.O. Box 64975 St. Paul, Minnesota 55164-0975 651/215-0792 ~+~'a ~~. Douglas J. Mandy, P-E., Supervisor Administrative Unit Section of Drinking Water Protection P.O. Box 64975 St. Paul, Minnesota 55164-0975 651/215-0757 DJM:JFC:rdp cc: City of Albertville Plowe Enginee.ring, Inc. File \ TOTAL P.07 10/30/00 MON 14:41 [TX/RX NO 8142]