Loading...
Parkside Commerical Center 10904 57th St NE (5) BIG PLANS0 E 0 0 :2 U) 0 E E 0 E a C 0 LL- 2 C*4 Co 4 0) tK I FJ )NC. SLAB -ON -GRADE ^4 COMPACTED SAND T- ION, TOP OF SLAB kTION = 100*-0" THROUGHOUT) r - -I L J SLAB CONTROL ISTRUCTION JOINT 5'-0" O.C. EA. WAY. Sl AND 3/Sl FJ L7 _J -- - - - - --- - - - - - -- - - - - - - - - ------------------------ !J 8'--7 1/2" 4'-0" -JIT r7o]l 11 Q, /Q1 BAR 2'-0" AT 2'-0" O.C. 119'-8 1/2" A TYPICAL SLAB CONSTRUCTION JOIIINT 1/8" SAW CUT TYPICAL SAWCUT SLAB CONTROL JOINT 21'-2 1/2" FOUNDATION PLAN 2x6 TREATED BOTT.- PLT. W/ 1/2"Ox`10" EMBEDMENT ANCHOR BOLTS 0 48" O.C. SLAB, SEE PLAN COMPACTED GRANULAR FILL, SEE PLAN FOOTING, - SEE PLAN 0 0 TYP. ALL EXT. WALLS 1/2" PLY. SHEATHING FASTENED WITH 10d NAILS @ 6" O.C. MAX. BRICK VENEER, SEE ARCH. 6" HALF MASONRY TOP COURSE FINISHED FLOOR Ah, TYPICAL DETAIL SCALE: 3/409 = 10-000 GENERAL STRUCTURAL NOTES: 1. BUILDING CODE: STRUCTURAL DESIGN CONFORMS TO THE REQUIREMENTS OF THE 2000 INTERNATIONAL BUILDING CODE (IBC) WITH STATE OF MINNESOTA AMENDMENTS 1 2. DESIGN LOADS: L J- WIND LOAD BASIC WIND SPEED (3 SECOND GUST) .................... 90 MPH WIND IMPORTANCE FACTOR, I .................................. 1.0 EXPOSURE................................................................. B INTERNAL PRESSURE COEFFICIENTS, GC ................ ±0-18 pi AOC' I nAr) LN LIVELOAD (L.L.) ....................................................... 40 PSF DEAD LOAD (DESIGN D.L.) ........................................ 15 PSF 3. ROOF SNOW LOAD: GROUND SNOW LOAD, Pg ............................................. 50 PSF FLAT ROOF SNOW LOAD, Pf ........................................ 40 PSF SNOW EXPOSURE FACTOR, Ce ............................. ­ .... ** 1.0 SNOW LOAD IMPORTANCE FACTOR, I .......................... 1.0 THERMAL FACTOR, Ct ................................................... 1.0 PLUS SNOW ACCUMULATION AS REQUIRED BY IBC, CHAPTER 16, SECTION 1608. COORDINATION: 1. STRUCTURAL MEMBERS INCLUDING SLABS, BEAMS, JOISTS, 0 COLUMNS AND WALLS ARE DESIGNED FOR "IN PLACE LOADS' Q1. I -00 CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING, WITHOUT LO OVERSTRESSING, ALL STRUCTURAL ELEMENTS (AS REQUIRED AT ANY STAGE OF CONSTRUCTION) UNTIL COMPLETION OF 7 0) -0 THIS PROJECT. FOUNDATIONS: 1. FOOTINGS WERE DESIGNED FOR A MAXIMUM SOIL BEARING PRESSURE OF 2500 PSF. SOIL BEARING PRESSURE SHALL BE VERIFIED PRIOR TO THE CONSTRUCTION OF THE FOOTINGS AND REPORT. ANY DISCREPANCIES TO THE ENGINEER. LOWER THE EXISTING FOOTING ELEVATIONS SHOWN IF NECESSARY TO OBTAIN THE REQUIRED BEARING PRESSURE. CONCRETE: 1. ALL CONCRETE SHALL BE NORMAL WEIGHT (150 PCF.) MINIMUM 28 DAY COMPRESSIVE STRENGTH, AS SPECIFIED BELOW: FOOTINGS AND FOUNDATION WALLS ............ 3000 PSI. SLAB ONGRADE .......................................... 4000 PSI. 2. PROVIDE 3" CLEAR COVER ON BOTTOM AND SIDES FOR FOOTING REINFORCING. 3. MAX. DISTANCE BETWEEN SLAB CONTROL OR CONSTRUCTION JOINTS SHALL NOT EXCEED 15'-0" 4. EXCEPT WHERE OTHERWISE SHOWN, SLABS ON GRADE SHALL BE REINFORCED WITH 6x6-10/10 WELDED WIRE MESH OR FIBERMESH. 5. EXCEPT WHERE OTHERWISE SHOWN, SLABS ON GRADE SHALL BE 4" THICK CONCRETE. REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM (GRADE 60). ol 2. WELDED WIRE FABRIC SHALL BE NEW BILLET STEEL, COLD DRAWN AND CONFORMING TO ASTM A185 AND A82. 3. BAR SUPPORTS, DESIGN, DETAILING, FABRICATION AND e- PLACING OF REINFORCING BARS AND MESH SHALL BE IN ACCORDANCE WITH THE ACI CODE AND DETAILING MANUAL. FIL CORES AND REINFORCE 4. UNLESS NOTED OTHERWISE, ALL REINFORCING LAP SPLICES Wfll 2 #5 VERTICAL AT ALL SHALL BE 40 BAR DIAMETERS OR 12", WHICHEVER IS GREATER. GIRDER TRUSS BRG. WCATIONS (12 THUS, WOOD TRUSSES: I 191CLUDING BUILDING 1 . ROOF TRUSSES SHALL BE DESIGNED FOR A TOP CHORD CfORNERS). SUPERIMPOSED SNOW LOAD OF 40 PSF (10 PSF DEAD LOADS) AND) A BOTTOM CHORD LOAD OF 5 PSF. 2. SUBMIT CERTIFIED CALCULATIONS WITH THE SHOP DRAWINGS. 3. REFER TO DRAWINGS FOR REQUIRED CONFIGURATION, PITCH, OVERHANG, ETC... 4. PROVIDE GIRDER TRUSSES, HIP -JACKS, STEP-DOWN TRUSSES, ETC. AS REQUIRED. 5. PROVIDE METAL FRAMING ANCHORS AT TRUSS BEARING LOCATIONS. 6. NO FIELD MODIFICATIONS OF ROOF TRUSSES SHALL BE ALLOWED WITHOUT THE WRITTEN APPROVAL OF THE TRUSS MANUFACTURER. DIMENSIONAL LUMBER: 1. FABRICATION AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICAPON FOR STRESS GRADE LUMBER AND ITS FASTENINGS 2. ALL MEMBER SIZES SHOWN ON PLANS ARE NOMINAL DIMENSIONS. 3. DIMENSION LUMBER SHALL BE DOUG. FIR, HEM FIR OR S-P-F, NO. 2 OR BETTER. 4. UNLESS NOTED OTHERWISE, ALL NAILING SHALL BE IN I ACCORDANCE WITH TABLE 2304.9.1 OF THE BUILDING CODE. 5. ALL BEAMS AND JOISTS NOT BEARING ON SUPPORTING MEMBERS SHALL BE FRAMED WITH JOIST HANGERS. 6. WOOD MEMBERS SHALL BEAR THE FULL WIDTH OF SUPPORTING MEMBERS UNLESS OTHERWISE NOTED. MASONRY: 1. CONCRETE MASONRY UNITS SHALL CONFORM TO THE REQUIREMENTS OF ASTM C90. 2. MINIMUM COMPRESSIVE STRENGTH OF MSY. UNITS F'm 1500 PSI. 3. GROUT FOR HOLLOW MASONRY UNITS SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. AND SHALL BE NORMAL WEIGHT PEA GRAVEL CONCRETE. 4. ALL VERTICAL REINFORCING SHALL BE CONTINUOUS WITH 40 BAR DIAMETER LAPS AT SPLICES UNLESS NOTED. SPECIAL INSPECTIONS AND TESTING SCHEDULES: .Specification Pomnnrf Section Description_ Type of Firm Freq�ency Assigned Firm T-.+!- (Z^kmAi ilzo TABLE 1704.4 CONCRETE FOUNDATION TA 1 SET100 CY 1803 GRADING AND FILLING TA CALL CONT. ACKNOWLEDGMENTS Owner: Contractor: &a Architec SER: * SI: * Sh TA: TA: F: F: Firm: ---Date- Firm: -----Date: Firm: __LAMPERT ARCHITECTS -Date: 06.03.U!�' Firm: STROH ENGINEERING. --Date: 06.03.05 Firm: ----Date: --- -- Firm: ---Date: Firm: - - - - -----Date: - - - - - - - - Firm: - - - - - - - - - - - - - - Date: Firm: ---Date: Firm: ---Date: - - - - - - 1128 SIBLEY MEMORIAL HIGHWAY MENDOTA HEIGHTS. MN 55118 PHONE 651-H5H-9H55 PAX 651-H5H-5086 ENGINEER CERTIFICATION: I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE BERNIE STROH PRINT NAME LICENSE NO. 06.03.05 DATE ce LLJ 0 UJ U < U < CL LU 010 0 U Structural Engineer: BERNIE S. Drawn By. PAE Checked By. BS Revisions 04.05.05 CHECK SET 06.03.05 1 ISSUED FOUNDATION PLANI NOTES AND DETAILS Sheet Number . si. Project No. 041027-1