Loading...
Addition Permit Handout Date Received BUILDING PERMIT APPLICATION Date Notified A�Ibcrt ille 5959 Main Avenue NE Date Paid Albertville, MN 55301 Ck, Cash, CC Small Town Living.Sig t6u:µp Ute. Phone: 763.497.3384 Fax 763.497.3210 Permit# - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Site Address: BUILDING PERMIT FEES Business Name: The Applicant is: Owner Contractor Tenant I Permit Legal Description:PID# Surcharge Addition Lot Block Owner: I Plan Check Name Address I Engineering(site) City State Zip I Mechanical Email I Fireplace(s) I I Phone (H) (W) (C) I Plumbing I I Contractor: I Sewer Company Name License# I I Water Address City St Zip Water Meter I I Contact Person Email I City WAC I I Phone: (W) (C) (Fax) I 1P WAC I I I Architect: I SAC Name Address Storm Water City State Zip License Check E-Mail I I Other Phone (W) (C) (Fax) I TOTAL I I Type of Work: New Construction Residential Addition Alteration Finish Bsmt I Type of Const. New Construction Commercial - Garage/Shed - Reside/Reroof - Fireplace I Use of Bldg Tenant Finish Plbg Htg Deck I I Description of Work: I Occupancy Group Occupancy Load I I Size of Structure: Total Square Footage: Length First Floor I Zoning Width Second Floor Height Basement I Code Used Garage I Are Fire Sprinklers Required? I Estimated Valuation of Work: $ I 11 Yes 0 No Separate permits are required far electrical,plumbing heating or fireplace. I hereby apply for the ahnve consideration and declare that the infornnation and materials submitted with this application.are in compliance with City Ordinance and Policv Require- I Date Approved ments and are complete and accurate to the best of aw knowledge. It is applicants responsibility to locate and establish the elevations,if needed,of all site improvements. Required adjurtment..r at owners'expense. I�nderstan that all Ci v incvt ed Fire Dept• professional fees and expenses associated with the processing of this request are the responsibility of the property owner and/or applicant and will be promptly paid. 7f payment is not received from the applicant,the property owner acknowledges and agrees I City Engineer to be responsible. Applicants Signature Applicants Printed Name Date Notify of Assoc&Covenant — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Public Works Approved by Building Official Value Approved Date City Planner Special Conditions or Comments: Public Data/Building Department/Applications/Building Permit Applications 8-25-15 A 1t ADDITION PERMIT HANDOUT INFORMATION REQUIRED FOR A BUILDING PERMIT TO CONSTRUCT A ROOM ADDITION 1. Signed and completed Building Permit Application. 2. Submit two copies of a current Certificate of Survey,drawn to scale,indicating the lot dimensions,the location and dimensions of existing structure(s) and the location and dimensions of the proposed structure. Indicate the setbacks from property lines and wetlands/buffers (if applicable). 3. Submit two copies of exteriors envelope calculations which comply with the State Energy Code (forms are available from our front service counter). Questions regarding compliance and in completing the form should be directed to an architect,a professional builder or your lumber supplier. 4. Submit two copies of plans showing proposed designs and materials. Plans shall be drawn to scale and shall include the information listed below: A. A foundation plan indicating: ■ All proposed strip and pad footings,both exterior and interior. ■ Footing/foundation, dimensions and construction materials. ■ Whether crawl space, slab-on-grade or full basement. ■ Size, spacing and direction of floor joists. B. A floor plan indicating: ■ Proposed layout of new rooms and existing adjacent rooms (label rooms as to use). ■ Dimensions of building addition and individual rooms. ■ Location and size of window and door openings. ■ Size of window and door headers. ■ Type and size of any existing support members. ■ Skylight size,type and location. C. A cross section indicating: ■ Footing/foundation design, dimensions and construction materials. ■ Exterior wall design, dimensions and construction materials. ■ Floor and roof design, dimensions and construction materials. ■ Venting methods at soffit and roof. D. An elevation plan indicating: ■ Front and side views of the proposed addition. ■ Approximate height of the addition. ■ Location of all doors and windows. ■ Size of roof overhangs. ■ Roof pitch. ■ Location of roof vents. A 1t LAND-US RESTRICTIONS: Minimum required setback distances from the front, side and rear lot lines may vary according to location. They are set by the Zoning Ordinance and approved plans. Contact the Planning Department for this information. NOTE: Locating the property corner irons (legal markers) is the responsibility of the property owner; irons must be visible when the footing inspection is requested. Setbacks are measured from the legal property line,wetlands or buffer (if applicable). CODE REQUIREMENTS: Your room addition should be designed in accordance with the provisions of the Minnesota State Building Code. If you have questions regarding specific code requirements,please contact the Building Inspection Department at 763-497-3384 ext103. Questions regarding design and costs should be referred to a professional builder or architect. REQUIRED INSPECTIONS: 1. Footings-To be made after the trenches have been excavated and all forms and reinforcing steel have been erected erosion control devices installed and prior to the placement of concrete. 2. Framing-To be made after the roof,all framing,fire blocking and bracing are in place and all pipes,chimneys and vents are complete and the rough electrical,plumbing and heating wires,pipes and ducts are approved. 3. Insulation-To be made after the framing inspection has been approved and prior to placement of any interior wall covering. 4. Final-To be made after all plumbing,mechanical and electrical systems have been completed and approved and the addition is ready for occupancy. GENERAL NOTES: 1. Plan review and Building Permit issuance normally require five working days from receipt of a complete application. You will be contacted when the permit is ready to pick up. 2. The City stamped"Approved" plan and survey must be kept on the job site until the final inspection has been made. 3. The inspection record card shall be placed on an outside exterior wall of the addition and shall remain posted until the final inspection has been made. Cards should be protected from the weather. 4. Separate permits are required when installing electrical wiring,plumbing and mechanical systems. 5. Any disturbed ground is required to have erosion control devices installed in order to prevent site erosion or siltation from occurring into City streets,wetland areas,ponds or lakes. 6. Smoke detectors shall be installed throughout the existing structure (in each sleeping room, in the corridor area giving access to each sleeping area and on each level). 7. Carbon Monoxide detector shall be installed within 10 feet of all bedrooms. 8. Call (763) 497-9923 during regular business hours to arrange for an inspection. A 1t MINIMUM CLEAR DIMENSIONS: 1. 2'6" Width for toilet 2. 3'0" Hall Width 3. 3'0" Stairway width 4. 7'6" Ceiling height in habitable rooms (living,sleeping,eating, cooking) NATURAL LIGHT: All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the floor area of such rooms. Natural ventilation shall be through windows, doors,louvers or other approved openings to the outdoor air. Such openings shall be provided with ready access or shall otherwise be readily controllable by the building occupants. The minimum openable area to the outdoors shall be 4 percent of the floor area being ventilated. FRAMING: Lumber shall be grade-stamped. The bottom wall plate shall be treated wood and securely fastened to the floor slab with nails/screws or construction adhesive. Engineered floor trusses/beams shall not be notched, or altered without written approval from the manufacturer. STAIRWAYS: Minimum stairway headroom clearance is 6' 8" (measured vertically from a plane parallel and tangent to the stairway tread nosing to the above at all points). Landings at the bottom of the stairways required 36" of depth before the door or the wall.All interior and exterior stairways shall be provided with a means to illuminate the stairs,including the landings and treads. ENCLOSED AREA UNDER STAIRS: The walls and ceiling of an enclosed space below an interior stairway shall be protected with one layer of 1/2"type X gypsum board. If the area is greater than 100 square feet,a heat run shall be provided to the area for ventilation. INSULATION: Foundation walls require R-10 insulation. Framed walls require R-21 insulation. Attic requires R- 49 insulation. Rigid foam insulation with a frame spread rating greater than 75 and/or a smoke density rating greater than 450 shall be protected with 1/z"gypsum board or 1/4"plywood. Bathtub trap openings and other penetrations in the floor above shall be filled with fiberglass or foam insulation. A vapor barrier (4 mil poly or equal) is required on the warm side of insulated exterior walls. This includes behind the showers and tubs on exterior walls. Water resistive gypsum board cannot be applied over another vapor barrier (such as 4 mil poly), or on ceilings. CERAMIC TILE: Ceramic tile in the shower/tub area shall be applied over concrete board. A 1t SAFETY GLAZING: Safety glazing is required in doors and enclosures for hot tubs,whirlpools,saunas,steam rooms, bathrooms and showers. Glazing in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60"above the walking surface. Safety glazing is required in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60"above the walking surface. MECHANICAL: All habitable rooms shall be provided with a heating system capable of maintaining 72 degrees Fahrenheit at a point three feet above the finished floor. Main trunk lines are to be adequately sized to allow additional supply branch ducts to be provided to any additional finished rooms. Provide return air ducts,the same size as the supply ducts,to all rooms but the kitchen and bathroom. Each bathroom requires an exhaust fan to the exterior. The ducts shall be insulated to an R-4.2 the first three feet from the exterior wall,and terminate at least three feet from any opening such as an openable window or combustion air duct in the exterior wall. PLUMBING: An access panel is required for hose bib shutoff valves and upper level tub traps. A shower or combination shower/bath must be equipped with an anti-scald type shower control valve. The valve must be the thermostatic or pressure-balancing type. ELECTRICAL: A separate State Electrical Permit is required for any new wiring and must be obtained by the person doing the work. FOR ELECTRICAL INSPECTION CALL PAUL HIPSAG at 763-241-2102 between 7am and 8:30am. A 1t SAMPLE OF SITE PLAN 1 INCH = FEET EXPOSED PROPERTY IRON PROPOSED GARAGE :PROPOSED: € PORCH (show direction) EXISTING HOUSE PROPERTY FRONT PROPOSM LINES YARD DRIVE A\1bertville Addition Plan Information Handout illustrationsThese Existing Addition Elevation Your drawings must be to scale. ROOF Scale 1/4-= 1' These examples show the detail required for plan VENT submittals to the Building and Inspection Division. From your drawings, plan reviewers should be able to build the project themselves. The following are required when submittting proposals: • Two sets of plans, drawn to scale. • A minimum of one elevation, one plan view per floor level and one section view per area being added. • A survey/plot plan showing the location of your project. Call or visit the Building and Inspection Division to see if your property has a survey available. • Although you do not need to draw plumbing, electrical or heating plans, separate permits are From siding required. The building permit covers only structural, to grade insulation and finish products. A—minimum 6"" CONCRETE BLOCK GRADE Plan view: Foundation • Locate addition in relation to existing home. • Indicate whether the addition is a crawl space, full depth foundation or post footings. • Include written dimensions and locations. Plan view: Foundation • If it is being built on post footings, the footings must Laundry with crawl space be sized for submittal of plans. room Scale 1/4-= 1' See graphic at right,below and page 2. 10'-0- ------------------------ Rec Plan view: ' room --------------------- -- Foundation - --- --- --1Foundation with posts2 x a JolsTs 8""x 16- Scale 1/4-= 116-O.C. 131 FOOTING ,1 ,1 Bedroom i J' 10'-0" 24-FOOTING 187x 24- ^' ACCESS '1 ' Addition 1 ; n, Addition 2""x 8-JOISTSo11/2" ---------------- Family 16-O.C.room 18-FOOTING ___ ___ _____________2-2-x 8"BEAMS 8" CONCRETE BLOCK- 5 CourseR-15 FOAM INSULATION 24-FOOTING GYPSUM BOARD Note: Provide written distances between posts. Plan view: Floor • Draw to scale. • Note the scale you use on the drawing. • Include written dimensions on the plan. • Locate all doors and windows. • Provide rough opening sizes and U-values from the manufacturer for each window unit and door. • Provide header and beam sizes, as well as type of material being used. (e.g. 2 -2" x 10" Doug Fir or 2- 9-1/2" LVLs.) • Provide a floor plan for each level being built. • Indicate direction and spacing of joists, rafters/trusses, e.g. 12", 16" or 24" on center. • Indicate the use (e.g. bathroom, family room, bedroom) of the new room(s) and those adjoining the addition. See graphic below.(Note:Materials,types and sizes are given for example only.) First floor Scale 1/4-= 1' WINDOW Laundry Assembly size =X square feet or room Rough-opening =width times height GAS Description A* FIREPLACE 10'_ 0_ Family room HEADER HEATED Q Q ADDITION 2-2"x 8" M DOOR N HEADER p Q Q �a� Rough opening �. Q Q 3"- 3""x 6"- 10"" U-value=0.32 CD CONCRETE Cn Q �PATI0 Dining room 2- 2-x 10- 14 A* WINDOW Rough-opening =2 2""x 3"- 5" Vinyl clad/double hung/low-e/U-value =0.32 maximum Location of Section A-A on next page. Section view If more than one area is being built, provide one section (Note: Materials, types and sizes are given for example view for each area. See graphic below. only.) Section A -A 12 PITCH OF ROOF Scale 1/2"= 1" } �5 250#ASPHALT SHINGLES 15# FELT PAPER 6"ICE PROTECTION BARRIER R-49 BLOWN 1/2-CD-X PLYWOOD INSULATION AIR CHUTES � MFRD TRUSSES 24""O.C.or size of rafters and ceiling joists INSULATED 5/8"GYPSUM VAPOR 3/4"FASCIA BOARD ATTIC ACCESS BOARD RETARDER Rough opening size 4-Mil 22"X 30" �e ALUMINUM/VENTED SOFFIT R-20 FIBERGLASS INSULATION 2"x 6"STUDS 16""O.0 1/2"PLYWOOD SHEATHING WATER RESISTANT BARRIER 1/2-GYPSUM BOARD (Name specific housewrap and/or felt paper) SIDING (Type of material,e.g.vinyl, cedar,stucco,etc.) 3/4"TONGUE AND R-20 RIM GROOVE PLYWOOD INSULATION 2"x 8"JOISTS 2-X 6-TREATED SILL PLATE with sill sealer R-15 RIGID a 5 GRADE 18" CRAWL INSULATION I SPACE 1/2-GYPSUM I CHOIR BOLTS 42" MINIMUM a 3 2"X 9""at max 6"O.C. FOOTING DEPTH ° a°2 6 Mil Poly 8" CONCRETE VAPOR RETARDER BLOCK-5 Courses Extend up wall aT1 minimum of 6" and � a° a seal to rigid insulation 8"x 16""FOOTING Note: Include soil type at residence. (e.g. clay, gravel, sand.)