Addition Permit Handout Date Received
BUILDING PERMIT APPLICATION Date Notified
A�Ibcrt ille 5959 Main Avenue NE Date Paid
Albertville, MN 55301 Ck, Cash, CC
Small Town Living.Sig t6u:µp Ute.
Phone: 763.497.3384 Fax 763.497.3210 Permit#
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Site Address: BUILDING PERMIT FEES
Business Name:
The Applicant is: Owner Contractor Tenant I Permit
Legal Description:PID# Surcharge
Addition Lot Block
Owner: I Plan Check
Name Address I Engineering(site)
City State Zip I Mechanical
Email I Fireplace(s)
I I
Phone (H) (W) (C) I Plumbing
I I
Contractor: I Sewer
Company Name License#
I I Water
Address City St Zip
Water Meter
I I
Contact Person Email I City WAC
I I
Phone: (W) (C) (Fax) I 1P WAC
I I
I Architect: I SAC
Name Address
Storm Water
City State Zip
License Check
E-Mail
I I Other
Phone (W) (C) (Fax) I TOTAL
I I
Type of Work:
New Construction Residential Addition Alteration Finish Bsmt I Type of Const.
New Construction Commercial - Garage/Shed - Reside/Reroof - Fireplace I Use of Bldg
Tenant Finish Plbg Htg Deck
I I
Description of Work: I Occupancy Group
Occupancy Load
I I
Size of Structure: Total Square Footage:
Length First Floor I Zoning
Width Second Floor
Height Basement I Code Used
Garage I Are Fire Sprinklers Required?
I Estimated Valuation of Work: $ I 11 Yes 0 No
Separate permits are required far electrical,plumbing heating or fireplace. I hereby apply for the ahnve consideration and declare
that the infornnation and materials submitted with this application.are in compliance with City Ordinance and Policv Require- I Date Approved
ments and are complete and accurate to the best of aw knowledge. It is applicants responsibility to locate and establish the
elevations,if needed,of all site improvements. Required adjurtment..r at owners'expense. I�nderstan that all Ci v incvt ed Fire Dept•
professional fees and expenses associated with the processing of this request are the responsibility of the property owner and/or
applicant and will be promptly paid. 7f payment is not received from the applicant,the property owner acknowledges and agrees I City Engineer
to be responsible.
Applicants Signature Applicants Printed Name Date Notify of Assoc&Covenant
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Public Works
Approved by Building Official Value Approved Date
City Planner
Special Conditions or Comments:
Public Data/Building Department/Applications/Building Permit Applications 8-25-15
A 1t
ADDITION PERMIT HANDOUT
INFORMATION REQUIRED FOR A BUILDING PERMIT TO CONSTRUCT A ROOM ADDITION
1. Signed and completed Building Permit Application.
2. Submit two copies of a current Certificate of Survey,drawn to scale,indicating the lot
dimensions,the location and dimensions of existing structure(s) and the location and
dimensions of the proposed structure. Indicate the setbacks from property lines and
wetlands/buffers (if applicable).
3. Submit two copies of exteriors envelope calculations which comply with the State Energy Code
(forms are available from our front service counter). Questions regarding compliance and in
completing the form should be directed to an architect,a professional builder or your lumber
supplier.
4. Submit two copies of plans showing proposed designs and materials. Plans shall be drawn to
scale and shall include the information listed below:
A. A foundation plan indicating:
■ All proposed strip and pad footings,both exterior and interior.
■ Footing/foundation, dimensions and construction materials.
■ Whether crawl space, slab-on-grade or full basement.
■ Size, spacing and direction of floor joists.
B. A floor plan indicating:
■ Proposed layout of new rooms and existing adjacent rooms (label rooms as to use).
■ Dimensions of building addition and individual rooms.
■ Location and size of window and door openings.
■ Size of window and door headers.
■ Type and size of any existing support members.
■ Skylight size,type and location.
C. A cross section indicating:
■ Footing/foundation design, dimensions and construction materials.
■ Exterior wall design, dimensions and construction materials.
■ Floor and roof design, dimensions and construction materials.
■ Venting methods at soffit and roof.
D. An elevation plan indicating:
■ Front and side views of the proposed addition.
■ Approximate height of the addition.
■ Location of all doors and windows.
■ Size of roof overhangs.
■ Roof pitch.
■ Location of roof vents.
A 1t
LAND-US RESTRICTIONS:
Minimum required setback distances from the front, side and rear lot lines may vary according to
location. They are set by the Zoning Ordinance and approved plans. Contact the Planning
Department for this information.
NOTE: Locating the property corner irons (legal markers) is the responsibility of the property
owner; irons must be visible when the footing inspection is requested. Setbacks are measured from
the legal property line,wetlands or buffer (if applicable).
CODE REQUIREMENTS:
Your room addition should be designed in accordance with the provisions of the Minnesota State
Building Code. If you have questions regarding specific code requirements,please contact the
Building Inspection Department at 763-497-3384 ext103. Questions regarding design and costs
should be referred to a professional builder or architect.
REQUIRED INSPECTIONS:
1. Footings-To be made after the trenches have been excavated and all forms and
reinforcing steel have been erected erosion control devices installed and prior to the
placement of concrete.
2. Framing-To be made after the roof,all framing,fire blocking and bracing are in place and
all pipes,chimneys and vents are complete and the rough electrical,plumbing and heating
wires,pipes and ducts are approved.
3. Insulation-To be made after the framing inspection has been approved and prior to
placement of any interior wall covering.
4. Final-To be made after all plumbing,mechanical and electrical systems have been
completed and approved and the addition is ready for occupancy.
GENERAL NOTES:
1. Plan review and Building Permit issuance normally require five working days from receipt
of a complete application. You will be contacted when the permit is ready to pick up.
2. The City stamped"Approved" plan and survey must be kept on the job site until the final
inspection has been made.
3. The inspection record card shall be placed on an outside exterior wall of the addition and
shall remain posted until the final inspection has been made. Cards should be protected
from the weather.
4. Separate permits are required when installing electrical wiring,plumbing and mechanical
systems.
5. Any disturbed ground is required to have erosion control devices installed in order to
prevent site erosion or siltation from occurring into City streets,wetland areas,ponds or
lakes.
6. Smoke detectors shall be installed throughout the existing structure (in each sleeping room,
in the corridor area giving access to each sleeping area and on each level).
7. Carbon Monoxide detector shall be installed within 10 feet of all bedrooms.
8. Call (763) 497-9923 during regular business hours to arrange for an inspection.
A 1t
MINIMUM CLEAR DIMENSIONS:
1. 2'6" Width for toilet
2. 3'0" Hall Width
3. 3'0" Stairway width
4. 7'6" Ceiling height in habitable rooms (living,sleeping,eating, cooking)
NATURAL LIGHT:
All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the
floor area of such rooms. Natural ventilation shall be through windows, doors,louvers or other
approved openings to the outdoor air. Such openings shall be provided with ready access or shall
otherwise be readily controllable by the building occupants. The minimum openable area to the
outdoors shall be 4 percent of the floor area being ventilated.
FRAMING:
Lumber shall be grade-stamped. The bottom wall plate shall be treated wood and securely fastened
to the floor slab with nails/screws or construction adhesive. Engineered floor trusses/beams shall
not be notched, or altered without written approval from the manufacturer.
STAIRWAYS:
Minimum stairway headroom clearance is 6' 8" (measured vertically from a plane parallel and
tangent to the stairway tread nosing to the above at all points). Landings at the bottom of the
stairways required 36" of depth before the door or the wall.All interior and exterior stairways shall
be provided with a means to illuminate the stairs,including the landings and treads.
ENCLOSED AREA UNDER STAIRS:
The walls and ceiling of an enclosed space below an interior stairway shall be protected with one
layer of 1/2"type X gypsum board. If the area is greater than 100 square feet,a heat run shall be
provided to the area for ventilation.
INSULATION:
Foundation walls require R-10 insulation. Framed walls require R-21 insulation. Attic requires R-
49 insulation. Rigid foam insulation with a frame spread rating greater than 75 and/or a smoke
density rating greater than 450 shall be protected with 1/z"gypsum board or 1/4"plywood.
Bathtub trap openings and other penetrations in the floor above shall be filled with fiberglass or
foam insulation.
A vapor barrier (4 mil poly or equal) is required on the warm side of insulated exterior walls. This
includes behind the showers and tubs on exterior walls. Water resistive gypsum board cannot be
applied over another vapor barrier (such as 4 mil poly), or on ceilings.
CERAMIC TILE:
Ceramic tile in the shower/tub area shall be applied over concrete board.
A 1t
SAFETY GLAZING:
Safety glazing is required in doors and enclosures for hot tubs,whirlpools,saunas,steam rooms,
bathrooms and showers. Glazing in any portion of a building wall enclosing these compartments
where the bottom exposed edge of the glazing is less than 60"above the walking surface.
Safety glazing is required in fixed or operable panels adjacent to a door where the nearest exposed
edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and
where the bottom exposed edge of the glazing is less than 60"above the walking surface.
MECHANICAL:
All habitable rooms shall be provided with a heating system capable of maintaining 72 degrees
Fahrenheit at a point three feet above the finished floor.
Main trunk lines are to be adequately sized to allow additional supply branch ducts to be provided
to any additional finished rooms. Provide return air ducts,the same size as the supply ducts,to all
rooms but the kitchen and bathroom.
Each bathroom requires an exhaust fan to the exterior. The ducts shall be insulated to an R-4.2 the
first three feet from the exterior wall,and terminate at least three feet from any opening such as an
openable window or combustion air duct in the exterior wall.
PLUMBING:
An access panel is required for hose bib shutoff valves and upper level tub traps. A shower or
combination shower/bath must be equipped with an anti-scald type shower control valve. The
valve must be the thermostatic or pressure-balancing type.
ELECTRICAL:
A separate State Electrical Permit is required for any new wiring and must be obtained by the
person doing the work.
FOR ELECTRICAL INSPECTION CALL PAUL HIPSAG at 763-241-2102 between 7am and 8:30am.
A 1t
SAMPLE OF SITE PLAN
1 INCH = FEET
EXPOSED
PROPERTY IRON
PROPOSED
GARAGE
:PROPOSED:
€ PORCH
(show direction)
EXISTING
HOUSE
PROPERTY
FRONT PROPOSM LINES
YARD DRIVE
A\1bertville Addition Plan
Information Handout
illustrationsThese Existing Addition Elevation
Your drawings must be to scale.
ROOF Scale 1/4-= 1'
These examples show the detail required for plan VENT
submittals to the Building and Inspection Division. From
your drawings, plan reviewers should be able to build
the project themselves.
The following are required when submittting proposals:
• Two sets of plans, drawn to scale.
• A minimum of one elevation, one plan view per
floor level and one section view per area being added.
• A survey/plot plan showing the location of your
project. Call or visit the Building and Inspection Division
to see if your property has a survey available.
• Although you do not need to draw plumbing,
electrical or heating plans, separate permits are From siding
required. The building permit covers only structural, to grade
insulation and finish products. A—minimum 6""
CONCRETE BLOCK GRADE
Plan view: Foundation
• Locate addition in relation to existing home.
• Indicate whether the addition is a crawl space, full
depth foundation or post footings.
• Include written dimensions and locations. Plan view: Foundation
• If it is being built on post footings, the footings must Laundry with crawl space
be sized for submittal of plans. room Scale 1/4-= 1'
See graphic at right,below and page 2.
10'-0-
------------------------
Rec
Plan view: '
room --------------------- --
Foundation
- --- --- --1Foundation with posts2 x a JolsTs 8""x 16-
Scale 1/4-= 116-O.C. 131 FOOTING
,1
,1
Bedroom i J'
10'-0" 24-FOOTING 187x 24- ^'
ACCESS '1 '
Addition 1 ;
n, Addition
2""x 8-JOISTSo11/2"
----------------
Family 16-O.C.room 18-FOOTING ___ ___ _____________2-2-x 8"BEAMS 8" CONCRETE BLOCK- 5 CourseR-15 FOAM INSULATION
24-FOOTING GYPSUM BOARD
Note: Provide written distances between posts.
Plan view: Floor
• Draw to scale.
• Note the scale you use on the drawing.
• Include written dimensions on the plan.
• Locate all doors and windows.
• Provide rough opening sizes and U-values from the manufacturer for each window unit and door.
• Provide header and beam sizes, as well as type of material being used. (e.g. 2 -2" x 10" Doug Fir
or 2- 9-1/2" LVLs.)
• Provide a floor plan for each level being built.
• Indicate direction and spacing of joists, rafters/trusses, e.g. 12", 16" or 24" on center.
• Indicate the use (e.g. bathroom, family room, bedroom) of the new room(s) and those adjoining
the addition.
See graphic below.(Note:Materials,types and sizes are given for example only.)
First floor
Scale 1/4-= 1'
WINDOW
Laundry Assembly size =X square feet or
room Rough-opening =width times height GAS
Description A* FIREPLACE
10'_ 0_
Family
room
HEADER
HEATED Q Q
ADDITION
2-2"x 8" M DOOR
N
HEADER p Q Q �a� Rough opening
�. Q Q 3"- 3""x 6"- 10""
U-value=0.32
CD
CONCRETE
Cn Q �PATI0
Dining room
2- 2-x 10-
14
A*
WINDOW
Rough-opening =2 2""x 3"- 5"
Vinyl clad/double hung/low-e/U-value =0.32 maximum
Location of Section A-A on next page.
Section view
If more than one area is being built, provide one section (Note: Materials, types and sizes are given for example
view for each area. See graphic below. only.)
Section A -A 12
PITCH OF ROOF
Scale 1/2"= 1" }
�5 250#ASPHALT SHINGLES
15# FELT PAPER
6"ICE PROTECTION BARRIER
R-49 BLOWN 1/2-CD-X PLYWOOD
INSULATION AIR CHUTES
� MFRD TRUSSES
24""O.C.or size of rafters
and ceiling joists
INSULATED 5/8"GYPSUM VAPOR 3/4"FASCIA BOARD
ATTIC ACCESS BOARD RETARDER
Rough opening size 4-Mil
22"X 30" �e ALUMINUM/VENTED SOFFIT
R-20 FIBERGLASS INSULATION
2"x 6"STUDS 16""O.0
1/2"PLYWOOD SHEATHING
WATER RESISTANT BARRIER
1/2-GYPSUM BOARD (Name specific housewrap and/or
felt paper)
SIDING
(Type of material,e.g.vinyl,
cedar,stucco,etc.)
3/4"TONGUE AND R-20 RIM
GROOVE PLYWOOD INSULATION
2"x 8"JOISTS 2-X 6-TREATED
SILL PLATE with sill sealer
R-15 RIGID a 5 GRADE
18" CRAWL INSULATION
I SPACE 1/2-GYPSUM I CHOIR BOLTS 42" MINIMUM
a 3 2"X 9""at max 6"O.C. FOOTING DEPTH
° a°2
6 Mil Poly 8" CONCRETE
VAPOR RETARDER BLOCK-5 Courses
Extend up wall aT1
minimum of 6" and � a° a
seal to rigid insulation
8"x 16""FOOTING