New Commercial Handout A,lbertville
Small"I'm un Uving.Big ClIty Lots.
NEW COMMERCIAL HANDOUT
The City of Albertville Building Inspections Department requires the following information be provided
with submittal of a New Commercial Building Permit Application.
Two (2) copies of a Certified Lot Survey
Two (2) Full Sets of Building Plans and one (1) reduced set of plans no larger than 11 x 17
and one electronic copy
PLAN SUBMITTAL REQUIREMENTS:
1. Architectural
a. All plans must be prepared and signed by a Licensed MN Architect in accordance
with State Statute.
b. Cover sheet must include Code Analysis Information for project
C. Architectural drawings must include elevation drawings of exterior view of front,
rear,and sides of finished structure
d. Floor plans showing the dimensions of the space,location of equipment,
bathrooms, emergency exits,interior walls,fire rated walls,stairways,plumbing
and mechanical equipment
e. Section drawings (side cutaway view) showing the details of the footing
through the roof
f. Provide copies of the floor and roof truss specifications prepared and stamped by
a Licensed MN Engineer on it
g. Architect shall submit one (2) hard copies of all addendums
h. Energy Calculations-to verify the work meets the State Energy Code
2. Engineering
a. Civil drawings must be prepared and signed by a Licensed MN Engineer
b. Civil plans must include grading, drainage,and utility plans
C. Utilities plans must include location of sewer and water from street to structure
d. Fire service must be indicated from street to structure
e. Location of fire department connection must be identified
REVISION DATE 05/20/2019
f. Location of fire hydrants within 300 feet of property line
g. Must submit copies of all soil reports to the City
❑ h. All lots that are part of a subdivision in which an NPDES Storm Water permit was
required must submit a copy of the permit or Subdivision Registration form as
well as the Storm Water Pollution Prevention Plan (SWPPP) for the site.
i. Estimates of SAC&WAC charges may be provided by our City Engineer when
requested; charges are due at permit issuance
❑ j. Upon the completion of the final lot grading and site improvements,the permittee
shall submit to the City of Albertville an as-built survey showing that the final lot
grading and site improvements are in compliance with the plans approved for the
site. A final Certificate of Occupancy will not be issued until as-built has been
approved.
3. State
a. Two sets of plumbing plans prepared and signed by a Licensed MN
Master Plumber
b. Restaurants or establishments selling any sort of food products must submit
plans to the MN Dept. of Health
C. Elevators- any project installing elevators or related devices must apply to the
MN Dept. of Labor&Industry(visit www.doli.state.mn.us)
e. An electrical permit must be obtained by the State,visit
http://www.dli.mn.gov/business/electrical-contractors. Electrical Inspector is
Paul Hipsag 763-241-2102
f. Special Inspector Testing Agency form will be required as specified in the 2015
Minnesota State Code,Chapter 17
4. City of Albertville
a. City license required for all Sewer and Water Contractors.
b. A fire department key box is required prior to issuance of a certificate of
occupancy and may be purchased at the city. Boxes are available in surface mount
and flush mount. Contact City Hall for more information.
C. The City of Albertville has a dumpster cover Ordinance # 2003-01
All dumpsters must be covered with a secure cover or tarp.
REVISION DATE 05/20/2019
A,1bcrtvi,11l`C
Small Town Living.Big Cn,µUe.
5959 Main Avenue N.E.
P.O. Box 9
Albertville, MN 55301
As-Built Survey Requirements
(Commercial Lot)
Upon the completion of the final lot grading and site improvements, the permittee shall
submit to the City of Albertville an as-built survey/plans showing that the final lot
grading and site improvements are in compliance with the plans approved. A registered
Minnesota land surveyor and/or engineer, as specified, shall sign as-builts.
The certification shall contain at a minimum the following information:
1. As-built finish floor elevations.
2. As-built footprint of buildings
3. As-built footprint of parking lot and driveways.
4. As-built grade elevations of building corners.
5. As-built top of curb elevations at all corners, high points, low points, and at a
minimum interval of 100'.
6. As-built spot elevations of all graded retention ponds, swales and wetlands.
7. As-built ground elevation at all emergency overflow (EOF)locations.
8. As-built ground elevation at all lot corners.
9. As-built rim and invert elevations at all manholes (storm and sanitary sewer).
10. As-built locations of sewer and water services.
11. As-built pipe lengths and grades for storm sewer and sanitary sewer lines.
12. As-built top nut of hydrant elevations.
13. As-built swing ties to all gate valves, curb stops and cleanouts. The maximum
swing tie length is 100 feet and the swing ties must be made to manholes,
catch basins, hydrants and/or permanent building corners.
14. As-built retaining wall elevations along top and bottom of wall.
15. Identify all wetland delineations and wetland demarcation.
16. As-built 100 Year HWL/OHWL contour of any water features (ponds,
wetlands, etc.).
17. As-built elevations of all storm water conveyance swales and drainage ways.
18. Verification that all property corners are in place as of this date.
Updated 1/22/08 an
Date Received
Ile BUILDING PERMIT APPLICATION Date Notified
A,Ibertvi 5959 Main Avenue NE Date Paid
Small.rows.„Living.Big Cfty Life. Albertville, MN 55301 Ck, Cash, CC
Phone: 763.497.3384 Fax 763.497.3210 Permit#
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Site Address: BUILDING PERMIT FEES
Business Name:
The Applicant is: Owner Contractor Tenant I Permit
Legal Description:PID# Surcharge
Addition Lot Block
Owner: I Plan Check
Name Address I Engineering(site)
I I
City State Zip I Mechanical
Email I Fireplace(s)
I I
Phone(H) (W) (C) I Plumbing
I I
Contractor: I Sewer
Company Name License#
I I Water
I Address City St Zip
Water Meter
I I
Contact Person Email I City WAC
I I
Phone: (W) (C) (Fax) I JP WAC
I I
Architect: I SAC
Name Address
Storm Water
I City State Zip
I I License Check
E-Mail
Other
Phone (W) (C) (Fax)
I I TOTAL
I Type of Work:
HNew Construction Residential Addition Alteration Finish Bsmt I Type of Const.
New Construction Commercial Garage/Shed Reside/Reroof Fireplace I Use of Bldg
Tenant Finish Plbg Htg Deck
I I
Description of Work: I Occupancy Group
I I
Occupancy Load
Size of Structure: Total Square Footage:
Length First Floor I Zoning
Width Second Floor I Code Used
Height Basement
Garage
Estimated Valuation of Work: $ I Are Fire Sprinklers Required:'
Yes []No
Separate permits are required jor electrical,plumbing,heating or fireplace. 1 herehy apply for the above consideration and declare
that the information and materials submitted with this application are in compliance with City Ordinance and Policy Require- I Date Approved
ments and are complete and accurate to the best of mp knowledge. It is applicants responsibility to locate and establish the
elevations,if needed,of all site improvements. Required adjustments at owners expense. I understand that all City incurred I Fire Dept•
professional fees and expenses associated with the processing of this request are the respansihility of the property owner and/or
applicant and will be promptly paid Ifpayment is not received from the applicant,the proper y owner acknowledges and agrees I City Engineer
to be responsible.
Applicants Signature Applicants Printed Name Date Notify of Assoc&Covenant
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Public Works
Approved by Building Official Value Approved Date
City Planner
Special Conditions or Comments: