Loading...
1993-08-03 Planning Report ~~ Northwest Associated Consultants, Inc. URBAN PlANNING.DESIGN.MARKET RESEARCH PLANNING REPORT TO: Albertville Mayor and City Council Albertville Planning Commission FROM: Elizabeth Stockman/David Licht DATE: 3 August 1993 RE: Albertville - Parkside Second Addition FILE NO: 163.06 - 93.03 EXECUTIVE SUMMARY Background: Kenco Construction, Inc. has submitted a preliminary plat of Parks ide Second Addition for consideration by the City. The project encompasses Outlots A & B of the original Westwind Plat. The plans show 18 base lots and 36 unit lots for the development of duplex homes on 6.67 acres. The site is zoned PUD, Planned Unit Development, and is located on the south side of CSAH 37, just northwest of parkside 1st Addition. Attached for Reference: Exhibit A - Site Location/Zoning Exhibit B - Preliminary Plat Recommendation: Based upon the nature of this matter, as well as the issues highlighted in the following review, we believe that the decision to approve or deny the development request is a policy decision to be made by the City Council. Their consideration and review of the applicant's request must take into account the issues which have been outlined below. It is recommended that the City Council thoroughly review these factors as part of a decision on the request. 5775 Wayzata Blvd.' Suite 555' St. Louis Park. MN 55416. (612) 595-9636'Fax. 595-9837 Issues 1. Several proposed lots fall below the R-3 lot area standard of 12,500 square feet. 2. All but two proposed lots fall below the R- 3 lot width standard of 90 feet. 3. All structures are setback 25 feet from the right-of-way rather than the 35 foot minimum as stipulated in the R-3 District standards. Besides.a design character issue, this matter also poses parking concerns. 4. The character of the neighborhood may be negatively influenced by the close proximity and identical construction style of homes on substandard lots. Conditions Upon review of issues identified herein by the City Council, it is recommended that if the project is favored, the following conditions be attached to potential approval of the proposed preliminary plat: 1. Minimum lot size and setback requirements are established by the City if deviation from zoning district standards is to be allowed through the PUD. 2. Typical building plans, including elevation drawings, are submitted by the developer which indicate housing style, dimensions, height, and materials. 3. All grading, drainage, utilities and streets are reviewed and approved by the City Engineer. 4. A landscape plan be submitted to the City for review and comment; which includes some type of screening along CSAR 37. 5. Park dedication requirements are met as outlined herein. 6. The developer demonstrate that lots with area less than 12,500 square feet are able to accommodate the maximum allowable accessory building square footage and other allowances to be stipulated in the protective covenants. 7. A declaration of covenant is established and filed with the County Recorder which requires lot owners to maintain the designated screening areas and stipulates desired performance standards not covered by City Zoning Ordinance regulations. 2 8. A homeowners association is established or the protective covenants include a stipulation which gives the City the right to enforce all deviations from performance standard requirements. 9. A security deposit is required to ensure that all work occurs according to approved plans. 10. A development contract is prepared by the city and accepted by the applicant prior to final plat submission. ISSUES ANALYSIS Comprehensive Plan. The proposed plat is located within Planning District One of the city's Comprehensive Plan. The subject site is designated for medium density residential development. In March of 1993, a Comprehensive Plan amendment was adopted which limited multiple family dwellings to 33 percent (one-third) of the total housing stock in the City. This policy includes apartment dwellings only, and does not limit the establishment of duplexjtwo- family homes. Additionally, the surrounding area high density residential, low density residential and commercial land uses are compatible with the proposed development. The request to construct duplex homes as shown on the preliminary plat is therefore consistent with the intent of the Comprehensive Plan. Zoninq. The subject site is zoned PUD, Planned Unit Development. As such, all permitted, permitted accessory, or conditional uses contained in residential zoning districts are potentially permitted uses wi thin the PUD District. The original intent of the PUD District as it was originally established for the Westwind project was to allow for substantial deviations in performance standards such as lot size and building setbacks. However, these deviations were not specifically identified within the Westwind developers agreement for Outlots A and B and the provisions of the City Zoning Ordinance therefore are applicable as written. Two family dwelling units are permitted uses in the R-2, R-3, and R-4 Residential Zoning Districts. The R- 3, single and two family district contains the leasf restrictive standards and will therefore be utilized to evaluate the proposed development. 3 Lot Size and Setback Requirements Lot Area: Lot Width: Setbacks - Front: Side: Rear: 12,500 sf (base lots) 90 feet Not less than 35 feet Not less than 10 feet from adjacent lots, nor less than 20 feet on a side yard abutting a public right-of-way. 25 feet The base lot sizes shown on the proposed plat range from 12,000 square feet to 29,967 square feet. There are four lots below the 12,500 square foot minimum lot size standard. The average lot size is 16,175 square feet. The unit lot sizes range from 6,000 square feet to 18,686 square feet, at an overall average of 8,087 square feet. The lot widths range from 80 feet to 103 feet wide. All but two lots are below the 90 foot required lot width. The number of proposed lots with lot widths less than the 90 foot R-3 standard raises concerns in relation to the character of the neighborhood and proximity of structures to one another. Rows of nine duplex homes on both sides of the street which have identical sizes and appearances may not be desirable when numbers of parked vehicles and other outdoor storage items are visible in association with the structures on subsequent lots. While all side and rear setbacks have been met, the front yard setbacks are shown at 25 feet rather than the 35 foot required minimum. The declaration of covenants pertaining to the PUD states that any house constructed on any lot shall meet all setback requirements of the City Ordinances. Additionally, the proposed front yard setback of 25 feet raises concerns relative to the parking of vehicles and recreational vehicles in the driveway. The 25 foot driveway length would not allow the space necessary to park vehicles two deep and be completely upon the private property. The 35 foot recommended setback would allow ample driveway length for these purposes. It should be noted, however, that adjacent single family homes are setback 25 feet and the developer feels that this sets a precedent which should be upheld. Buildinq ..Heiqht. The maximum building height of all principal structures may not exceed 25 feet. Elevation drawings have not been submitted to date, thus evaluation of this factor should occur upon receipt of building plans which will be required prior to approval of the plat. 4 Accessory Buildinqs/Outdoor Storaqe. The need for accessory structures and space for the storage of outdoor equipment and recreational vehicles is anticipated on many of the properties in Parks ide 2nd Addition, as with all types of residential development. The proposed lot sizes, lot widths and building setbacks raise concerns relative to the amount of yard and driveway area available to comply with zoning district standards. The developer has indicated, however, that restrictive covenants will be established which limit the size of accessory structures to less than the City .standard and that the outdoor storage of vehicles/equipment will be prohibited. Draft documents which address these factors will be required prior to final plan approval. Lot Coveraqe. The Zoning Ordinance requires that no structure or combination of structures shall occupy more than thirty (30) percent of the lot area. The proposed duplex homes encompass approximately 2,630 square feet and are in compliance with this requirement on all proposed lots. The smallest base lot is 12,000 square feet, of which 30% lot area equals 3,600 square feet. Streets. The proposed alignment of Kahler Drive is consistent with the approved concept plan and Parks ide 1st Addition to the south. The street is shown at the required 60 foot right-of-way width. The street section grading and design will be subject to review by the City Engineer. Gradinq and Drainaqe. The developers agreement established as part of the Westwind proj ect requires that a grading, drainage and erosion control plan be submitted for approval by the City. No plan(s) have been submitted to date and will be required prior to plat approval. Utilities. A utility plan will be required for the proposed plat showing all existing and proposed utility lines or easements. A utility plan should be submitted for the city Engineer's review and comment prior to plat approval. Architectural Compatibility. Buildings in all zoning districts must maintain a high standard of architectural and aesthetic compatibility to ensure that they will not adversely impact adjacent properties or the overall city image. As mentioned previously, . typical building plans should be submitted for review by the City. Landscape Plan. A landscape plan will be required prior to plat approval and should be submitted by the developer. The plan must show the location of all existing and proposed vegetation and site amenities. The plan should also include some type of vegetative or man-made buffer along CSAH 37 to screen the potential adverse effects of traffic noise and visibility as required in the Westwind Development Agreement. Screening between the adjacent 5 . . commercially zoned land and the Kenco Property is the responsibility of the adjacent property owner should commercial uses ever be developed there. It would be beneficial for residents, however, if some trees were planted in this location so that they will have time to mature prior to future development. Park Dedication. As stipulated in the original Westwind developers agreement, a park dedication amount of $10,000 and 14.2 acres was established to satisfy the ordinance requirements for the balance of single family lots and the first phase of multiple-dwelling development. This does not include the Parks ide 2nd Addition, which will require that additional cash paYments or land dedication be. submitted. The proposed subdivision contains a total of 36 dwelling units per 6.67 acres, which results in 5.4 dwelling units per one acre. The city park dedication standards require that in areas of less than 9 dwelling units/acre, 5 percent of the gross land area or $170.00 per dwelling unit be provided. This results in .33 acres, $6,120, or a combination thereof, which will be required and must be agreed to between the developer and the City prior to plat approval. Protective Covenants. The developer is required to prepare a declaration of covenants as required in the original Westwind Development Agreement, to be filed with the Wright County Recorder, which establishes the screening required along CSAH 37. It should state that affected lot owners in the plat must maintain the established screening at all times satisfactory to the City. It should also be noted that the developer does not wish to establish a homeowners association because all lots are to be privately owned and maintained. While the protective covenants can include specified maintenance and performance standard requirements, a special stipulation would have to be included which would allow the City to enforce them. The City Attorney has recommended that a homeowners association be established, however, if the City Council chooses to allow the developer's request, the following items must be included as part of the declaration of covenants: 1. Standards for building and yard maintenance. 2. Accessory building allowances. 3. Prohibition of outdoor storage uses (as desired by the developer) . 4. Stipulation which gives the City the right to enforce the stated deviations from City performance standards. A draft document should be submitted for review by the City Attorney prior to final plan approval. 6 . , Securities. A security deposit will be required by the City to ensure that all developer installed improvements, completion of specified construction work, and establishment of landscaping/screening occurs according to approved plans. Develooment Contract. A development contract will be required and prepared by the city which should be agreed to by the applicant prior to final plat submission. CONCLUSION The decision to approve or deny the Parks ide 2nd Addition is a policy decision which must be made by the City Council due to the apparent desire by the developer to deviate from minimum Zoning Ordinance performance standards. While thePUD designation does allow for flexibility in this regard, it is questionable whether or not the reduced lot standards are warranted in this case. The intent of the PUD district is to provide for the establishment of a more desirable, innovative and creative development by utilizing higher standards of site and building design in areas of unique land features. The proposed subdivision does not appear to contain any of these characteristics. It is therefore recommended that consideration be given to maintaining the R-3 Zoning Ordinance standards as outlined herein and that the conditions as listed in the Executive Summary of this report are met to the satisfaction of the City. pc: Ann Culley Kenco Construction, Inc. Mike Couri Thore Meyer 7 ... << ... ... o III o " x << u ... '" I I I - - -'- - -----4------ I I I I I :;; .. ~ .. o. .O~ ij ~J c :;::) a. ,... . <2: . ',:"'';';i,;..."". C'? . OJ I I I ---1----------- I ,.../ c:i:1 I I I I I -+------ I I I I EXHIBIT A 1 " ! I · = ~ I i . ! ~ ~. I , . , l::: " :: = ! I ~ . '-r' ~ I ! I r .. .... i .i .'(r ....~ .. .;'i ~(> . ;; r ! i ;: i ~ ttB ' . 1 , . <-.~ ~ ,,{". .. . l <0 . .~ ~ ..:0 ~ ~u -0 { ~ Y" ~ .~ ~ "7 ~ ~ t . "" -""-', ~ ~;;;;;;;;;;;;::::: ~~~~~E5E::~~8ggggg ~ ~~~:~~:~~~;..~~::~ ~l ~3ls~S~3~~~ i :l~ ~,1:~~~!~1::~~111111 t.;. ..J..).3~~~~ClQO~()'t()......... ~...l...l..l";..l..l~j~.3 ... III 0:: ::0. .. III .5 .5 Ql .. 0.. z o I- o o <tj 00.. Z ~ o .2 o ~ WO UJ~ W CI 0:5 as UJo ~ a: <t a. ')'; ~ ... J/: t .,=, . ~ l: ; ~ ~ .~ .. ~ ! g ! ~ . . < - . J I -I v ~ .s ~ N ~ c 1: ~ I .g ~ ... ::0. ~ i I v E ~ a:l -t ~ . ::l ~ "t:I ). .. ~ IU 0 b ~ ~ ~ Cl) s u. '" .!? .. C ~ I III ., 1; ! i 0 N I Q, u z Cl) !l ~d ~ E .. .:3 0 :i! 0.. 1 t!- v ~ ~ " c Q) ~ .~ ~ ;:! N f; " .. i .g ~ .. ,:: < j g u ] 0 .. : u .. 6 ~ i ! ~ Q f ~ .; ~ - .;: ~ . i ~~ ! ~ ! ~ ~ ~ I r " < " . ~ ~~i . . .. ..;) ... . ~ t::":S :.~ E ~ . ! l . ~ ;; c3 a il ", '6 < !C" <1 I- -;; "! .. ~~ II! i!1 J ! ='~~W-f\l-?JID-' . 1! 1- .1 jf[.';, . ~', : :,:*W (;j ! I ~ . 'Ii EX ....,............... HIBIT B